Well Designed Safe Dual Pump Vacuum Transformer Oil Regeneration Plant

Product Details
Customization: Available
Certification: CE
Application: Transformer Oil
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)
  • Well Designed Safe Dual Pump Vacuum Transformer Oil Regeneration Plant
  • Well Designed Safe Dual Pump Vacuum Transformer Oil Regeneration Plant
  • Well Designed Safe Dual Pump Vacuum Transformer Oil Regeneration Plant
  • Well Designed Safe Dual Pump Vacuum Transformer Oil Regeneration Plant
  • Well Designed Safe Dual Pump Vacuum Transformer Oil Regeneration Plant
  • Well Designed Safe Dual Pump Vacuum Transformer Oil Regeneration Plant
Find Similar Products

Basic Info.

Model NO.
ZYD-I-100
Folw Rate
100 L/min
Color
Gray, Blue, Yellow, etc.
Function
Removing Water, Gas, Impurities, etc. and Decolori
Advantages
Purification, Regeneration and Decoloration
Pump
Vacuum Pump and Roots Pump
Online Filtration
Can Be Connected with Transformers
Transport Package
Wooden Case
Specification
1200x950x1500 mm
Trademark
TOP Oil Purifier
Origin
Chongqing, China
HS Code
8421299090
Production Capacity
100 Sets/ Month

Product Description

ZYD-I Series
Double-Stage Vacuum Transformer Oil Purifier

(ZYD-I-100)

Well Designed Safe Dual Pump Vacuum Transformer Oil Regeneration Plant

Application

ZYD-I machine is specially designed for on site use to completely regenerate insulating oils in energized or de-energized transformers. It not only provides regular oil purification including degassing, drying and particulate removal but also removes acidity, sludge, other soluble oil decay products, and improves color. For special application, the system also can be mounted on a leak proof base or be installed and operated on a trailer.

Features

1. For special application, the operation can be controlled by P.L.C (Programmable Logic Controller) (ZYD-I-A Series).
2. Unique vacuum dehydration, degassification and regeneration system, adopt stereo-evaporation technology. Duplex 3D stereo-evaporation, eliminating the liquid water quickly
3. UK g technology by which the trace water that is show chain, such as dissolved water, can be removed effectively.
4. Advanced infrared liquid-level automatic control system to accomplish fully automatic control.
5. Can be applied for vacuum oiling and drying power transmission equipment.
6. Special additives for depolarization can recover oil color of aged transformer oil to new.


Working Principle

The insulating oil is conveyed into the degassing tank by means of pressure difference. Oil is indirectly heated by the heater, thus avoiding hot spots and over-swinging of the pre-selected operating temperature. The special degassing system and geometry with several stages in degassing tank creates a large oil surface and a resulting thin film for most effective maximum degassing. The treatment with a lower end vacuum (-0.08 to -0.095 MPa) guarantees, among others, that no light fractions are evaporated in the insulating oil, whereby the required characteristics of the oil are not changed.

The oil level regulation in the degassing tank assures a continuous oil flow-through in the plant, thus resulting in an optimised degassing of the oil.

After degassing and dehydration under vacuum, the oil is conveyed by means of a specially sealed and frequency controlled pump into regeneration system. Then oil through the fine filter and out of the plant.


Technical Parameter
 
Parameter Unit ZYD-I-30 ZYD-I-50 ZYD-I-100 ZYD-I-150 ZYD-I-200 ZYD-I-250 ZYD-I-300
Flow rate L/h 1800 3000 6000 9000 12000 15000 18000
Working vacuum MPa -0.08~-0.099
Working pressure MPa ≤0.3
Temperature range ºC 20 ~ 80
Power   3 ph 380V 50Hz (Or as needed)
Working noise dB(A) 75 75 75 75 80 80 80
Heating power kW 30 30 45 60 75 90 120
Total power kW 35.5 37.5 52.5 71.4 86.5 102.5 135
Oil Inlet/Outlet mm φ25 φ32 φ42 φ50 φ50 φ60 φ60
Weight Kg 600 800 1050 1400 1800 2000 2200
Overall L mm 1050 1100 1200 1450 1600 1800 1900
  W mm 750 800 950 950 1100 1200 1200
  H mm 1350 1400 1500 1650 1800 1900 1900
 
 
Item Unit After treatment
Breakdown Voltage kV ≥75
Moisture content PPM ≤3
Gas content % ≤0.1
Impurity size micron ≤1 (no free carbon)
IFT dynes/cm ≥40
Acid value mg KOH/g ≤ 0.03
Dielectric loss factors tgδ(90ºC) ≤0.001

Well Designed Safe Dual Pump Vacuum Transformer Oil Regeneration PlantWell Designed Safe Dual Pump Vacuum Transformer Oil Regeneration PlantWell Designed Safe Dual Pump Vacuum Transformer Oil Regeneration PlantWell Designed Safe Dual Pump Vacuum Transformer Oil Regeneration PlantWell Designed Safe Dual Pump Vacuum Transformer Oil Regeneration PlantWell Designed Safe Dual Pump Vacuum Transformer Oil Regeneration PlantWell Designed Safe Dual Pump Vacuum Transformer Oil Regeneration PlantWell Designed Safe Dual Pump Vacuum Transformer Oil Regeneration PlantWell Designed Safe Dual Pump Vacuum Transformer Oil Regeneration PlantWell Designed Safe Dual Pump Vacuum Transformer Oil Regeneration Plant
 