• Automatic/Manual Background Drift Correction Kf Volumetric Karl Fischer Titrator
  • Automatic/Manual Background Drift Correction Kf Volumetric Karl Fischer Titrator
  • Automatic/Manual Background Drift Correction Kf Volumetric Karl Fischer Titrator

Automatic/Manual Background Drift Correction Kf Volumetric Karl Fischer Titrator

Warranty: 1 Year
Type: Karl Fischer Moisture Meter
Analysis Method: Physical Analysis
Display: LED
Portable: Non-portable
Titrimetric Repeatability: 0.20%
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Chongqing, China
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)

Basic Info.

Resolution
1/30000
Transport Package
Wooden Case
Trademark
TOP TESTER
Origin
China
HS Code
9027
Production Capacity
1000 Sets/Month

Product Description

Automatic/manual background drift correction KF Volumetric Karl Fischer Titrator, 
TP-40VC Karl Fischer Titrator
 
  • Volumetric Karl Fischer Titration
  • Support KF Titration Mode and Titer Detection Mode.
  • Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals.
  • Automatic/manual background drift correction ensures accurate results.
  • Selectable units including mg, mg/L, %, ppm, etc.
  • Settable parameters, including measurement unit, polarization current, stirring rate, titration rate, stop volume, endpoint potential, stop criterion and etc.
  • Store up to 200 titration data sets (GLP-compliant).
  • Coulometric Karl Fischer Titration
  • Generator cell with diaphragm.
  • Automatic/manual background drift correction ensures accurate results.
  • Selectable units including pg, mg, %, ppm, mg/L,g/mL, etc.
  • Settable parameters, including measurement unit, polarization current, stirring rate, generator current, endpoint potential, stop criterion and etc.
  • Store up to 200 titration data sets (GLP-compliant).
  • GENERAL FEATURES
  • LCD display screen.
  • Titration methods, curves and results are displayed in detail.
  • Volumetric KF Titration and Coulometric KF Titration are supported.
  • Data analysis feature helps user review and compare results.
  • Data can be easily transferred to printer via RS-232 communication interface.
  • Reset feature automatically resumes all settings back to factory default options.
Coulometric electrolytic cup
Suitable for micro moisture samples
Model KFT-40VC
Volumetric Titration Range (0.1mg -250)mg
Polarization Current Accuracy 1pA±0.2pA, 50pA±10pA
Repeatability ±0.5%
Coulometric Titration Range 10pg~20mg
Polarization Current Accuracy 1pA±0.2pA, 50pA±10pA
Electrolytic Current 10mA, 20mA, 50mA, 100mA
Accuracy ± (5%+3) pg
Repeatability RSD of 100pg sample measurement result <3%
Automatic/Manual Background Drift Correction Kf Volumetric Karl Fischer TitratorAutomatic/Manual Background Drift Correction Kf Volumetric Karl Fischer TitratorAutomatic/Manual Background Drift Correction Kf Volumetric Karl Fischer Titrator