Super High Voltage Vacuum Aging Transformer Oil Reusing Machine

Certification: ISO/CE
Application: Transformer Oil
Voltage: 380V
Performance: Efficient Filtration
Structure: Mobile
Mechanical Principle: Vacuum
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Chongqing, China
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)

Basic Info.

Model NO.
ZYD Series
Type
Suction Filter
Usage
Oil and Gas Separation, Insulation Oil
Condition
New
Flow
1800-18000L/H
Working Pressure
0.3mpa
Dimension(L*W*H)
1050*750*1350mm
Transport Package
Standard Export Wooden Case
Specification
ISO/CE
Trademark
TOP Oil Purifier
Origin
Chongqing, China
HS Code
84212990
Production Capacity
100 Sets Per/Mouth

Product Description

High voltage vacuum used transformer oil refining plant, help maintain oil dielectric strength, safe operation


Introduction:
This vacuum transformer oil filtering plant is brought to the clients at competitive prices.
The Double Stage Transformer Oil Filter Machine undergoes rigorous quality control tests to make it devoid of all defects.
The machine is mainly used for electric power department and industries to deal with various oils
Such as transformer oil, mutual oil, switch oil, dielectric oil and so on. It also can be used for filtration of more than 110KV substation live line work on site.
Meanwhile, as the bridge-type vacuum linking system,
Series ZYD oil purifier can be used as independent vacuum source with functions of vacuum drying and vacuum oiling

Where is the series ZYD used?
This Double-stage Continuous On-Site Transformer Oil Treatment Plant Is Applied for Purifying the Insulation Oil in all kinds of large Power equipment, which Voltage larger than 110kv, altitude larger than 500M.

Attributes:
Capacity ranges from: 1000 LPH to 30000 LPH
Inlet Stainless Steel Filter is easy to clean and used to catch hold coarse dirt
Standard efficiency of 0.5 / 1 Micron after fine filter
Heat exchange through very low specific power electric heaters
To improve the vacuum pumping speed, vacuum pump set in combination with rotary vane vacuum pump and roots pump are provided
Easy to operate
Compact equipment is also provided with pneumatic wheels for easy transport on road
Duplex 3D stereo-evaporation technology, eliminating the liquid water very effectively
Distinctive removing impurities technology filtering through double FH trapezoidal network and absorbing by high polymer without the mechanical power
UK G technology by which the trace water that is show chain, such as dissolved water, can be removed effect
Carbon fiber infrared heating system that can make the oil contains zero sum of ethyne after treatment
Adopts the double-infrared liquid automatic controller, sensitive automatic pressure protector and the high effective equipment for degas, so it is easy to operat
Our Oil Purifier Advantage:
Comparing with the single-stage vacuum oil purifier, Series ZYD adds ROOTS vacuum system, second stage of separating system to improve the effect of purification which dewaters, degases and removes impurities more quickly, more completely and make the oils limiting voltage-withstand value much higher.
This machine also can remove free, soluble water, carbon, free and dissolved gases and particulate matters from insulating oil effectively and rapidly. Series ZYD utilizes coacervation technology, coalescing technology, separating technology and refined purification technology.

Optional Features:
An exhaust condenser to measure the extracted water
Condenser is equipped to settle the most volatile oil fractions which might distil back to the column
Digital temperature measurement
Digital precision vacuum gauge
Digital flow meter
Digital in line moisture content meter
Ionic reaction columns to remove the acidity from the oil
Audio / Visual fault annunciation System
PLC control system
Mobile Trailers can be provided
Fully-enclosed and Semi-enclosed for weather-proof are available
Index after purification
Water content≤ 5ppm
Gas content≤ 0.1%( by volume)
Acetylene content: 0
Breakdown voltage≥ 75KV (Spherical polar)
Particle qty in 100ml oil≤ 500 (5-50 micron), (0 for ≥ 100 micron particle).
Dielectric loss tgδ ≤ 0.3% (90° C)
Acid value ≤ 0.1mgKOH/g

Parameters

Unit

ZYD-30

ZYD-50

ZYD-100

ZYD-150

ZYD-200

ZYD-250

ZYD-300

Flow Rate

L/h

1800

3000

6000

9000

12000

15000

18000

Working vacuum

MPa

-0.08 ~ -0.099

Working Pressure

MPa

≤0.3

Temperature Range

°C

20 ~ 80

Power

 

Three Phase 50Hz,380V (or as needed)

Working Noise

dB(A)

70

70

70

75

75

75

75

Heating Power

KW

28

30

45

60

75

90

120

Total Power

KW

35.5

37.5

52.5

71.4

86.5

102.5

135

Inlet/Outlet

mm

φ25

φ32

φ42

φ50

φ50

φ60

φ60

Weight

Kg

600

800

1050

1400

1800

2000

2200

Overall

Length

mm

1050

1100

1200

1450

1600

1800

1900

Width

mm

750

800

950

950

1100

1200

1200

Height

mm

1350

1400

1500

1650

1800

1900

1900

Send your message to this supplier