• Power Station Transformer Oil Regeneration System
  • Power Station Transformer Oil Regeneration System
  • Power Station Transformer Oil Regeneration System
  • Power Station Transformer Oil Regeneration System
  • Power Station Transformer Oil Regeneration System

Power Station Transformer Oil Regeneration System

Structure: Fixed
Usage: Oil Impurities, Oil-Water Separator, Oil and Gas Separation
Type: Suction Filter
Mechanical Principle: Vacuum
Performance: Efficient Filtration
Flow Rate: 100 L/Min
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Chongqing, China
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)

Basic Info.

Model NO.
ZYD-I
Working Vacuum
-0.08 ~-0.099 Degree
Temperature Range
20 ~ 80 ºC
Working Pressure
<=0.3 MPa
Heating Power
48 Kw
Oil Inlet/Outlet
32 mm
Moisture Content (After Treatment)
<=3ppm
Breakdown Voltage (After Treatment)
>=75 Kv
Impurity Size (After Treatment)
<=1 Micron (No Free Carbon)
Gas Content (After Treatment)
<=0.1%
Transport Package
Standard Export Wooden Case
Specification
1800*1400*2450 mm
Trademark
TOP OIL PURIFIER
Origin
Chongqing, China
HS Code
84212990
Production Capacity
50/Month

Product Description


Product Description

Product Show:
Power Station Transformer Oil Regeneration System
Power Station Transformer Oil Regeneration System
Power Station Transformer Oil Regeneration System
Application:
The Oil regeneration system (Series ZYD-I) is specially designed for on-site use to completely regenerate insulating oils in energized or de-energized transformers. Besides dehydration, degasification and particulate removal, ZYD-I system also has the capability of removing acidity, sludge, and other soluble oil decay products and discolorizing oil. These are accomplished by the use of high vacuum degasification technology and particulate filters combined with our special brand of earth. After the treatment, the oil can be reused as new. For special application, the system can also be installed and operated on a trailer with a leak proof base.
Regular servicing of transformers with our equipment can substantially improve their lifetime and performance and on top helps to save money. 



Features:
1.The plant is delivered ready for operation. 
2.It provides regular oil purification but also removes acidity, sludge, other soluble oil decay products and discoloration.
3.Degasification, dehydration and filtration processes to purify various kinds of insulation oils in electrical transformers and circuit breakers through one or several passes. 
4. There are two vacuum pumps for plant ZYD-I (one is the vacuum pump, and the other one is the roots pump), which can improve the vacuum value highly, ensuring the water-content of the treated oil is less than 3 PPM.
5. All oil treatment plants, including series ZYD-I, are equipped with an automatic Anti-Foam Control System. 
6. The plant is equipped with built-in control and safety devices, which provide maximum operating security. 
7. Minimized power consumption through optimized degasification (an excellent efficiency factor). 
8. Standardized filter housing for 5 micron, 20 micron and 80 micron filter cartridges. 
9. Automatic supervision of the degree of contamination of the fine filter cartridges
10. ZYD-I can evacuate the electric equipment separately, such as the transformer. Also it can be used to dry the electric equipment and input the oil into the electric equipment under the vacuum state.
11.Reliable and automatic, The machine adopts the double-infrared liquid automatic controller, pressure automatic-protector which can make sure the machine works online for 150 hours continuously without person.
12. Adopt interlocked protective system, which connect oil pump, heater and liquid level sensor so as to avoid heating with no liquids, pumping with no liquids, oil leakage and electricity leakage. If there is any fault, machine will be power off automatically.
13. Functions of vacuum drying and vacuum oiling, as well as live-line working on site.

 
Technical Parameters: 
Parameters Unit ZYD-I
-30
ZYD-I
-50
ZYD-I
-100
ZYD-I
-150
ZYD-I
-200
ZYD-I
-250
ZYD-I
-300
Flow Rate L/min 30 50 100 150 200 250 300
Flow Rate L/H 1800 3000 6000 9000 12000 15000 18000
Working vacuum MPa -0.08 ~ -0.099
Working Pressure MPa ≤0.3
Temperature Range ºC 20 ~ 80
Power   AC380V/50HZ/3Ph 5 wire (can be customized)
Working Noise dB(A) 68 70 70 75 75 75 75
Heating Power kW 30 36 48 60 80 108 120
Total Power kW 36 44 54 70 93 120 135
Inlet/Outlet mm φ32 φ32 φ42 Φ42 Φ48 Φ60 Φ76
Weight kg 850 1000 1100 1250 2200 2600 3000
Overall L mm 1700 1750 1800 1900 2000 2150 2200
W mm 1200 1300 1400 1450 1500 1550 1600
H mm 2200 2250 2450 2450 2450 2450 2450
Index after filtering Breakdown Voltage kV ≥75
Moisture content PPM 3
Gas content % ≤0.1
Impurity size micron 1 (no free carbon)
Value β % 98
Cleanness NAS1638  6
Flash Point (Close) ºC ≥135
Acid value mg KOH/g 0.01
Interfacial tension N/m ≥145
Dielectric loss factor   ≤0.01
Color   Light yellow(close to water)

Product Details: 
Power Station Transformer Oil Regeneration System
Power Station Transformer Oil Regeneration System
Power Station Transformer Oil Regeneration System
Power Station Transformer Oil Regeneration SystemPower Station Transformer Oil Regeneration SystemPower Station Transformer Oil Regeneration System
Power Station Transformer Oil Regeneration System
Power Station Transformer Oil Regeneration System
Payment Terms:
MOQ 1 Set
Trade Terms EXW, FOB, CIF, CFR
Payment Terms T/T, L/C
Port of Loading Any Port of China
Packing Method Internaional Standard Wooden Case
Transportation Method By Sea, By Land, By Air, By Express
Supply Capability 100 Sets/Month

After-sale Service:
* The warranty period is 24 months from commissioning acceptance date on. After the warranty period is over we provide lifelong maintenance and technical service.
* We guarantee the maintenance time no more than 3 working days and response time within 1 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.


Power Station Transformer Oil Regeneration SystemPower Station Transformer Oil Regeneration System
WELCOME YOUR INQUIRY
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now