Insulating Oil Dielectric Loss and Resistivity Tester Tp-6100A (Automatic-Cleaning)

After-sales Service: 1 Years
Warranty: 1 Years
Condition: New
Power Supply: AC220V 10%, 50 Hz
Weight: 25 Kg
Display: English
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Chongqing, China
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)

Basic Info.

Model NO.
TP-6100A
Transport Package
Standard Export Wooden Case
Specification
ISO/CE
Trademark
TOP
Origin
Chongqing, China
HS Code
9027809900
Production Capacity
500 Sets Per/Mouth

Product Description

Introduction
TP-6100A Insulating oil dielectric loss and resistivity tester complies to ASTM D 924, IEC and GB/T5654-2007 Liquid Insulating Material Relative Permittivity, Dielectric Loss Factor And DC Resistivity Measurements. Used for measuring the dielectric loss factor and DC resistivity of insulation oil and other liquid insulating medium. The instrument is characterized by integrated structure, and integrates the dielectric loss of grease cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components. The instrument adopts intelligent automatic measurement, equipped with large screen (240*128) LCD display. Test results can be automatically stored and printed out so that the operator without professional training can use it easily.


Features


> Oil cup uses a three-electrode structure in line with GB / T5654-2007, the inter-electrode spacing of 2mm, can eliminate the impacts of stray capacitance and leakage impact on the dielectric loss test results. It has a drain solenoid switch, you can drain all the sample oil in the oil cup without removing the oil cup and rinse the oil cup with sample oil.

> The instrument uses mid-frequency induction heating, PID temperature control algorithm. This heating method has some advantages, eg, oil cup and heating body non-contact, heating evenly and quickly, also easy to control, thus the temperature strictly controlled within the preset temperature range of error.

> Internal standard capacitors for SF6 inflatable three-pole impact of capacitors, the capacitor dielectric loss and electrical capacity are not affected by ambient temperature, humidity etc to ensure that the instrument is still consistent accuracy after prolonged use.
> AC Test Power Supply with AC-DC-AC conversion, effectively prevent affecting of the dielectric loss test accuracy for the mains voltage and frequency fluctuations, even the generator generate electricity, the instrument can also run properly.

> Complete protection. When there is over-voltage, over-current, short-circuit for high-voltage, the instrument can be quickly cut off the voltage and warning. When the temperature sensor fails or is not connected, the instrument will give a warning message.
there is a limiting temperature relay amounted in the mid-frequency induction heating furnace, when the temperature exceeds 120 degrees, the relay release, then the heating stop.



> easy to set the parameters. Temperature setting range 0 ~ 125 ºC, the AC voltage setting range 500 ~ 2200V, the DC voltage setting range 0 ~ 500V.


> Large-screen LCD display with backlight, clear display. Friendly interface, simply follow the English menu prompt, enter the command, the instrument can be automatically tested. And automatically store and print test results.

> With real-time clock, test date and time can be saved with the test results, display and print.

> Empty electrode cup calibration. measuring capacitance and dielectric loss factor of empty electrode cup to determine the status of empty electrode cleaning and assembly of the cup. Calibration data is automatically saved, conducive to calculate the relative permittivity and DC resistivity precisely.

Technical Parameters

> Power supply: AC 220V ± 10%, 50Hz / 60Hz ± 1%
> Measuring range: capacity: 5pF ~ 200pF
  Relative permittivity: 1.000 to 30.000
  Dielectric loss factor: 0.00001 to 100
> DC Resistivity: 2.5 MΩm ~ 20 TΩm
> measurement Accuracy: Capacitance: ± (1% of reading + 0.5pF)
  Relative permittivity: ± 1% of reading
  Dielectric loss factor: ± (1% reading +0.0001)
  DC resistivity: ± 10% of reading
> Resolution: capacity: 0.01pF
  Relative permittivity: 0.001
  Dielectric loss factor: 0.00001


> Temperature range: 0 ~ 125 ºC
> Temperature measurement error: ± 0.5 ºC
> AC test voltage: 500 ~ 2200V continuously adjustable frequency 50Hz
> DC test voltage: 0 ~ 500V continuously adjustable
> Applicable Temperature: 0 ºC ~ 40 ºC
> Applicable Humidity: <75% RH
> Power: 100W

> Size: 500×360×420 mm
> Weight: 22Kg
 

Insulating Oil Dielectric Loss and Resistivity Tester Tp-6100A (Automatic-Cleaning)


Our oil tester
1. Transformer oil Breakdown voltage Tester (BDV test kit) series IIJ-II
2. Acidity tester model ACD-3000I
3. Karl Fischer Water content Tester Model TP-6A / model TP-2100
4. Fully automatic Interfacial Tension Analyzer model IT-800
5. Gas-Chromatography transformer oil gas analyzer model DGA2013-1
6. Multi-functional Vibration tester model TYD-2000
7. Consolidation Point Determinator model PT-2000
8. Kinematic Viscosity tester model VST-8 /model VST-2000
9. Flash point tester (open cup) model TPO-3000
10. Flash point tester (close cup) model TPC-3000
11. TAN-DELTA TESTER, 10kV Capacitance and Dissipation Factor Test Set model CDEF
12. Automatic Freezing Point & Pour Point Tester model TP-501Z
13. Determination of foaming characteristic of lubricating oil model SD-12579
14. Earth resistance tester model HYDW-II
15. Coil Resistance Tester (TPZC-40)
16. CT/PT tester model TPVA-404
17. Transformer turn ratio tester model HYG-II
18. Relaying Protection Tester model TPJB-III
19. Digital Grounding Resistance Tester model TP2571-II
20. DC High Voltage Generator model ZGF
21. Underground water/gold detector model TP-UWD
Insulating Oil Dielectric Loss and Resistivity Tester Tp-6100A (Automatic-Cleaning)
Insulating Oil Dielectric Loss and Resistivity Tester Tp-6100A (Automatic-Cleaning)
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now