Chongqing, China
Business Type:
Manufacturer/Factory & Trading Company
Number of Employees:
26
Year of Establishment:
2012-07-11
Management System Certification:
ISO 9001
Average Lead Time:
Peak season lead time: within 15 workdays
Off season lead time: within 15 workdays
OEM/ODM Service
Sample Available

Oil Dielectric Loss Tester, Tan Delta Testing Oil, Tangent Delta Tester manufacturer / supplier in China, offering IEC Insulation Oil DC Resistivity & Transformer Oil Dielectric Loss Factor (TP-6100A), Caster Transformer Oil Purification Machine to Extract Water (ZYD), Zyd-I Series Transformer Oil Purifier and Regeneration Deodorization Machine and so on.

Diamond Member Since 2014
Audited Supplier
Supplier Homepage Products Petroleum Products Testing Equipment IEC Insulation Oil DC Resistivity & Transformer Oil Dielectric Loss Factor (TP-6100A)

IEC Insulation Oil DC Resistivity & Transformer Oil Dielectric Loss Factor (TP-6100A)

Get Latest Price
Min. Order / Reference FOB Price
1 Set US $1-4,000/ Set
Production Capacity: 500 Sets/Month
Transport Package: Standard Export Wooden Case Per Set
Payment Terms: L/C, T/T, Paypal
Type: Universal Testing Machine
Weight: 0-100Kg
Power Source: 220V or as Per User′s Need
Condition: New Condition
Function: Test Oil Dielectric Loss Factor/DC Resistivity
Application: Insulation Oil and Other Liquid Insulating Medium

You Might Also Like

Loading...

Basic Info

Model NO.
TP-6100A
Feature
Portable and Economical
Customized
Power Supply and Other Requirements
Trademark
TOP
Specification
SGS, CE, ISO
Origin
Chongqing, China
HS Code
8421299090
Transformer Oil Loss Factor, Power Factor Measure,ASTM Oil Dielectric Loss Tester
(TP-6100A Model)

 
Introduction
TP-6100A Insulating oil dielectric loss and resistivity tester is based on IEC and GB/T5654-2007 design and manufacturing of Liquid insulating material of relative permittivity, dielectric loss factor and DC resistivity measurements. It is used for measuring dielectric loss factor and DC resistivity of insulation oil and other liquid insulating medium.
 
The instrument is characterized by integrated structure, and integrates the dielectric loss of grease cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components. The instrument adopts full digital technology and all of the intelligent automatic measurement, equipped with large screen (240*128) LCD display. The test results can be automatically stored and printed out so that the operator with no professional training will be able to use it proficiently.

Features
1. Grease cup complies to national standard GB/T5654-2007; three-electrode structure; inter-electrode space of 2mm; eliminate stray capacitance and leakage effects on dielectric loss test results.
 
2. Adopts the medium frequency induction heating and PID temperature control algorithm with advantages of non-contact oil cup and heating body, even heating, fast speed, convenient control, strict temperature control.
 
3. Internal standard capacitor of SF6 gas-filled three-electrode capacitance of the capacitor dielectric loss and electrical capacity independence of ambient temperature, humidity and other effects. The instrument accuracy is ensured even after prolonged use.
 
4. AC test power supply using AC-DC-AC conversion to effectively avoid fluctuations in mains voltage and frequency effect on dielectric loss measurement accuracy. Even a generator, the instrument can work properly.
 
5. Perfect protection function. When there is over voltage, over current or high-voltage short circuit, instrument can quickly cut off pressure and issues a warning message. When the temperature of the sensor fails or is not connected, the instrument will also issue a warning message.
 
6. There is a temperature limit relay in the medium frequency induction heating furnace. When temperature is above 120 degrees, the instrument frees the relay and stops heating.
 
7.More convenient the experimental parameter is set.Temperature setting range 0~125ºC, AC voltage setting range 500~2200V, DC voltage setting range 0~500V.
 
8. With large screen LCD with backlight and clear display. Friendly interface; Enter the commands, the instrument will automatically test, store and print test results.
 
9. Built-in real-time clock. Test date ans time can be retained with the test results, display and print.
 
10. Air electrode cup calibration function. Measurement air electrode cup capacitance and dielectric loss factor in order to determine air electrode cup cleaning and assembly condition. The calibration data is automatically saved in order to facilitate the calculation of relative permittivity and DC resistivity.
 
Technical Parameters
Power supply: AC220V±10%, 50Hz/60Hz ±1%
Measuring range:
Electric capacity 5pF~200pF
Relative capacitivity1.000~30.000
Dielectric loss factor0.00001~100
DC Resistivity2.5MΩm~20TΩm
Measuring accuracy:
Electric capacity± (1% of reading +0.5pF)
Relative capacitivity±1% of reading
DC Resistivity±10% of reading
Resolution:
Electric capacity0.01pF
Relative capacitivity0.001
Dielectric dissipation factor0.00001
Measured temperature range:0~125ºC
Temperature measurement error:±0.5ºC
Test Voltage AC(RMS):500~2200V Continuously adjustable, frequency 50Hz
Test Voltage DC:0~500V  Continuously adjustable
Power dissipation:100W
Dimension:500×360×420mm
Weight:22Kg
Working conditions:
Ambient temperature:0ºC~40ºC
Relative humidity(RH):<75%

 Trustable technical and after sale service
1. Long-term warranty of 2 years.
2. Provide best necessary spare parts at low price (some for free).
3. Provide timely reply and technical support within 24 hours.
4. OEM is available for TOP Products.
5. Protect your sales area, ideas of design and all your private information.
 


Related Testers
Transformer Testers
1. Transformer Load And No-load Tester TOFT 
2. Transformer Winding Deformation Tester TPWD-902
3. Transformer Capacity Tester TPTC
4. Transformer On-Load Voltage Regulation Switch Tester OLTC-2000
5. Transformer Turn Ratio Meter TPOM-901
6. Capacitance and Dissipation Factor Tester /Tan Delta Tester CDEF
7. DC Resistance Tester TPZC
 
Transformer Characteristics Testers
1. CT/PT Transformer Characteristics Comprehensive Tester TPVA-402
2. CT/PT Transformer Tester TPVA-404
3. Strong Current Generator SLQ
 
Insulating Oil Testers
1. Fully Automatic Insulating Oil Dielectric Strength Tester IIJ-II
2. Fully Automatic Insulating Oil Dielectric Strength Tester DYT
3. Fully Automatic Insulating Oil Dielectric Strength Tester DYT-2
4. Three Cups Insulating Oil Dielectric Strength Tester IIJ-III
5. Six Cups Insulating Oil Dielectric Strength Tester IJJ-VI
6. Insulating Oil Dielectric Strength Tester IIJ-603
7. Insulating Oil Tan Delta ( Dielectric Loss) Tester DLT0812
8. Insulating Oil Dielectric Loss And Resistivity Tester TP-6100A
9. Fully Automatic Water-Soluble Acid Value Tester PH-C
10. Fully Automatic Surface/Interface Tension Tester IT-800 
11. Fully Automatic Oil Acidity Tester (6 cups) ACD-3000I
12. Insulating Oil Gassing Property Tester DPT-20
13. Insulating Oil Oxidation Stability Tester TP622
14. Multifunctional Shaker SD-01
15. Insulating Oil Water Content Tester TP-2100
16. Online Insulating Oil Water Content Tester TPEE
17. Transformer Oil Dissolved Gas Chromatograph DGA
 
 Key words:  dielectric loss test, insulating oil dielectric loss tester, dielectric loss transformer oil tester, dielectric loss testing testing equipment, dielectric loss meter, insulating oil loss tester, transformer oil tester, oil dielectric loss tester, transformer dielectric loss, oil current resistivity tester, oil resistivity, oil loss factor tester, oil dielectric loss test, loss factor,power factor measure,tan delta tester

Send your message to this supplier