ASTM D2699 Portable Gasoline Octane Number Testing Equipment

Product Details
Customization: Available
After-sales Service: Provided
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)
  • ASTM D2699 Portable Gasoline Octane Number Testing Equipment
  • ASTM D2699 Portable Gasoline Octane Number Testing Equipment
Find Similar Products

Basic Info.

Model NO.
SX-300
Function
for Analysis of Octane Number and Gasoline Cetane
Transport Package
Standard Export Wooden Case
Trademark
SHATOX
Origin
Russia
HS Code
903109090
Production Capacity
100/Month

Product Description


ASTM D2699 Portable Gasoline Octane Number Testing Equipment

FOCUS ON OIL FILTRATION SYSTEM OVER 20 YEARS

Recycling your used oil reduces pollution and protects our environment.
Conserving a valuable resource and getting paid for it. 


                                                                                                                                                         Chongqing TOP Oil Purifier Co.,Ltd.

Product Description

Product Show:
ASTM D2699 Portable Gasoline Octane Number Testing Equipment
ASTM D2699 Portable Gasoline Octane Number Testing Equipment

ASTM D2699 Portable Gasoline Octane Number Testing Equipment
ASTM D2699 Portable Gasoline Octane Number Testing EquipmentWhether in the field or in the laboratory,this analyzers are leaders in portable rapid analysis instruments. We designs and produces analytical instruments for gasoline, diesel, motor oil and transformer oil.
Portable octane and cetane analyzers are often used for on-site analysis of octane number of power gasoline, corresponding to the motor method and research method (RON and MON), and also suitable for cetane number analysis of diesel. In addition, the temperature of the analyzed liquid and the freezing point of diesel can also be measured, and the measurement results are displayed on the LCD liquid crystal display. Octane and cetane analyzer is widely used all over the world. Its measurement method conforms to international standards: octane measurement conforms to: ASTM D 2699-86, ASTM D 2700-86; diesel cetane measurement conforms to: ASTM D 4737- 03, ASTM D 613, EN ISO 5165.
ASTM D2699 Portable Gasoline Octane Number Testing Equipment
1.Determining octane numbers for motor petrols; 2.Determining cetane numbers for diesel fuels; 3.Determining solidification temperature and diesel fuel type; 4.Content of antiknock compounds boosting the octane number of petrols; 5.Content of pour-point depressants for diesel fuels; 6.Content of kerosine in summer diesel fuel; 7.Petrol breakdown time (oxidative stability); 8.Loss angle tangent of circuit-breaker, machine and engine oil; 9.Level of engine, machine and circuit-breaker oil clarity; 10.Manufacturer, engine oil brand; 11.Engine oil base number; 12.Dielectric permeability of oil products; 13.Oil products volume resistivity; 14.Determining the mechanical impurities content in oil products; 15.Determining the cut. GOST 14203-69 - Oil and oil products. Dielectric humidity measuring method.
 
Measuring principle The principle of Octane Meter operation is in determining knock characteristic of gasoline, self-flammability of diesel fuel and in determining oil characteristics based on measurements of its dielectric permeability and volume resistivity.

ASTM D2699 Portable Gasoline Octane Number Testing Equipment#    Parameter description                                                                                      Measurement units                                    Value
1    Measured petrols octane numbers range                                                                            ON                                          40-135
2    Acceptable limit of octane number measurement basic error, max                                    ON                                             ±0.5
3    Limit of acceptable difference between parallel octane number measurements, max    ON                                               ±0.2
4    The determination range of antiknock additives content in petrols                                    %                                           0.5-15
5    Acceptable basic error limit of antiknock additives content determination in petrols    %                                                 0.1
6    Petrol oxidation breakdown time measurement range                                                     Min                                        50-2400
7    Acceptable basic error limit of petrol oxidation breakdown time                                    %                                                    5
8    Petrol quality determination mode basing on volume resistivity                                   Ohm                           10 6-10 14
9    Acceptable basic error limit of volume resistivity measurements                                    %                                                    3
10    Cetane numbers measurement range                                                                                    CN                                          20-100
11    Acceptable basic error limit of cetane numbers, max                                                            CN                                               ±1.0
12    Acceptable difference limit between cetane numbers parallel measurements, max    CN                                              ± 0.5
13    Acceptable error limit when determining diesel-fuel pour point                                             ºC                                                    2
14    Kerosine content determination range in summer diesel fuels                                               %                                            0-50
15    Acceptable basic error limit when determining kerosene content in diesel fuels               %                                                    3
16    Mode for pour point depressants content determination for diesel fuel                               %                                             0.2-1
17    Acceptable basic error limit when determining of pour point depressants content        %                                              0.01
18    Motor oils clarity level measurement range                                                                                %                                          50-100
19    Acceptable error limit of motor oils clarity level measurement                                                 %                                        0.1
20    Acceptable difference limit between motor oils clarity parallel measurements                 %                                      0.01
21    POL dielectric permeability measurement range                                                                       units                                        1-5
22    Acceptable error limit of dielectric permeability measurement, max                                        unit                                    0.001
23    Acceptable difference limit between POL dielectric permeability parallel measurements, max    unit                            0.001
24    Oils base number determination range                                                                                          unit                                      3-24
25    Acceptable basic error limit when determining oils basic number                                      BN unit                                            1
26    Motor oils manufacturer and brand determination                                                               Manufacturer                             -
27    Circuit-breaker oils (dielectrics) breakdown voltage measurement range                            kV                                   5-100
28    Acceptable error limit of circuit-breaker oils breakdown voltage measurement, max               kV                                            1
29    Acceptable difference limit between circuit-breaker oils breakdown time parallel measurements, max    kV                0.2
30    Measurement range of circuit-breaker oils loss angle tangent                                                    %                               0.01-40
31    Acceptable error limit of circuit-breaker oils loss angle tangent, max                                    %                                      0.01
32    Acceptable difference limit between circuit-breaker oils loss angle tangent parallel measurements, max  units    0.001
33    Determination range for mechanical impurities content in oil products                                     %                                  97-100
34    Acceptable basic error limit when determining mechanical impurities content in oil products    %                              0.01
35    Water-in-oil content determination range for oil products                                                              %                                      0-30                                             
36    Acceptable basic error limit when determining water-in-oil content of oil products              %                                            1
37    Measurement time                                                                                                                             sec                                       1-5
38    Insufficient power supply indication operation threshold                                                               V                                         5.4
39    Instrument useful life                                                                                                                                                                        6
40    Overall dimensions of:        
    electronic module    mm    100х210х40
    sensor #1 and #2    mm    60х100
    Instrument mass with one sensor/two sensors    g    850 / 680erall dimensions of: electronic module mm 100х210х40 sensor #1 and #2 mm 60х100 Instrument mass with one sensor/two sensors g 850 / 680
 
 
ASTM D2699 Portable Gasoline Octane Number Testing EquipmentASTM D2699 Portable Gasoline Octane Number Testing EquipmentASTM D2699 Portable Gasoline Octane Number Testing EquipmentASTM D2699 Portable Gasoline Octane Number Testing EquipmentASTM D2699 Portable Gasoline Octane Number Testing EquipmentASTM D2699 Portable Gasoline Octane Number Testing EquipmentASTM D2699 Portable Gasoline Octane Number Testing EquipmentASTM D2699 Portable Gasoline Octane Number Testing EquipmentASTM D2699 Portable Gasoline Octane Number Testing EquipmentASTM D2699 Portable Gasoline Octane Number Testing Equipment
1. who are we?
We are based in Chongqing, China, start from 2012,sell to Africa(11.00%),Mid East(11.00%),Southeast Asia(10.00%),Domestic
Market(8.00%),South Asia(7.00%),Eastern Asia(7.00%),North America(7.00%),South America(7.00%),Central America(7.00%),Eastern
Europe(6.00%),Oceania(5.00%),Western Europe(5.00%),Southern Europe(5.00%),Northern Europe(4.00%). There are total about 11-50
people in our office.

2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;

3.what can you buy from us?
Transformer Oil Purifier, Lubricating Oil Purifier, Oil Purification And Decoloration Machine, Cooking Oil Purification Machine,
Petroleum Products General Testers

4. why should you buy from us not from other suppliers?
Chongqing TOP Oil Purifier Co.,Ltd is a leading professional manufacture of oil purifiers from China. We practiced in this line
for more than 20 years and grown to be a full skilled team in tech research, operating, producing with rich experience.

5. what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,CIP,FCA,DDP,DDU,Express Delivery,DAF;
Accepted Payment Currency:USD,EUR,JPY,CAD,AUD,HKD,GBP,CNY,CHF;
Accepted Payment Type: T/T,L/C,Escrow;
Language Spoken:English,Chinese,Spanish,Portuguese,German,Arabic,French
 
WELCOME YOUR INQUIRY

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now