FOCUS ON OIL FILTRATION SYSTEM OVER 20 YEARS
Recycling your used oil reduces pollution and protects our environment.
Conserving a valuable resource and getting paid for it.
Chongqing TOP Oil Purifier Co.,Ltd. |
Product Description
Product Show:
ASTM D2699 Portable Gasoline Octane Number Testing Equipment
Whether in the field or in the laboratory,this analyzers are leaders in portable rapid analysis instruments. We designs and produces analytical instruments for gasoline, diesel, motor oil and transformer oil.
Portable octane and cetane analyzers are often used for on-site analysis of octane number of power gasoline, corresponding to the motor method and research method (RON and MON), and also suitable for cetane number analysis of diesel. In addition, the temperature of the analyzed liquid and the freezing point of diesel can also be measured, and the measurement results are displayed on the LCD liquid crystal display. Octane and cetane analyzer is widely used all over the world. Its measurement method conforms to international standards: octane measurement conforms to: ASTM D 2699-86, ASTM D 2700-86; diesel cetane measurement conforms to: ASTM D 4737- 03, ASTM D 613, EN ISO 5165.
1.Determining octane numbers for motor petrols; 2.Determining cetane numbers for diesel fuels; 3.Determining solidification temperature and diesel fuel type; 4.Content of antiknock compounds boosting the octane number of petrols; 5.Content of pour-point depressants for diesel fuels; 6.Content of kerosine in summer diesel fuel; 7.Petrol breakdown time (oxidative stability); 8.Loss angle tangent of circuit-breaker, machine and engine oil; 9.Level of engine, machine and circuit-breaker oil clarity; 10.Manufacturer, engine oil brand; 11.Engine oil base number; 12.Dielectric permeability of oil products; 13.Oil products volume resistivity; 14.Determining the mechanical impurities content in oil products; 15.Determining the cut. GOST 14203-69 - Oil and oil products. Dielectric humidity measuring method.
Measuring principle The principle of Octane Meter operation is in determining knock characteristic of gasoline, self-flammability of diesel fuel and in determining oil characteristics based on measurements of its dielectric permeability and volume resistivity.
# Parameter description Measurement units Value
1 Measured petrols octane numbers range ON 40-135
2 Acceptable limit of octane number measurement basic error, max ON ±0.5
3 Limit of acceptable difference between parallel octane number measurements, max ON ±0.2
4 The determination range of antiknock additives content in petrols % 0.5-15
5 Acceptable basic error limit of antiknock additives content determination in petrols % 0.1
6 Petrol oxidation breakdown time measurement range Min 50-2400
7 Acceptable basic error limit of petrol oxidation breakdown time % 5
8 Petrol quality determination mode basing on volume resistivity Ohm 10 6-10 14
9 Acceptable basic error limit of volume resistivity measurements % 3
10 Cetane numbers measurement range CN 20-100
11 Acceptable basic error limit of cetane numbers, max CN ±1.0
12 Acceptable difference limit between cetane numbers parallel measurements, max CN ± 0.5
13 Acceptable error limit when determining diesel-fuel pour point ºC 2
14 Kerosine content determination range in summer diesel fuels % 0-50
15 Acceptable basic error limit when determining kerosene content in diesel fuels % 3
16 Mode for pour point depressants content determination for diesel fuel % 0.2-1
17 Acceptable basic error limit when determining of pour point depressants content % 0.01
18 Motor oils clarity level measurement range % 50-100
19 Acceptable error limit of motor oils clarity level measurement % 0.1
20 Acceptable difference limit between motor oils clarity parallel measurements % 0.01
21 POL dielectric permeability measurement range units 1-5
22 Acceptable error limit of dielectric permeability measurement, max unit 0.001
23 Acceptable difference limit between POL dielectric permeability parallel measurements, max unit 0.001
24 Oils base number determination range unit 3-24
25 Acceptable basic error limit when determining oils basic number BN unit 1
26 Motor oils manufacturer and brand determination Manufacturer -
27 Circuit-breaker oils (dielectrics) breakdown voltage measurement range kV 5-100
28 Acceptable error limit of circuit-breaker oils breakdown voltage measurement, max kV 1
29 Acceptable difference limit between circuit-breaker oils breakdown time parallel measurements, max kV 0.2
30 Measurement range of circuit-breaker oils loss angle tangent % 0.01-40
31 Acceptable error limit of circuit-breaker oils loss angle tangent, max % 0.01
32 Acceptable difference limit between circuit-breaker oils loss angle tangent parallel measurements, max units 0.001
33 Determination range for mechanical impurities content in oil products % 97-100
34 Acceptable basic error limit when determining mechanical impurities content in oil products % 0.01
35 Water-in-oil content determination range for oil products % 0-30
36 Acceptable basic error limit when determining water-in-oil content of oil products % 1
37 Measurement time sec 1-5
38 Insufficient power supply indication operation threshold V 5.4
39 Instrument useful life 6
40 Overall dimensions of:
electronic module mm 100х210х40
sensor #1 and #2 mm 60х100
Instrument mass with one sensor/two sensors g 850 / 680
erall dimensions of: electronic module mm 100х210х40 sensor #1 and #2 mm 60х100 Instrument mass with one sensor/two sensors g 850 / 680
1. who are we?
We are based in Chongqing, China, start from 2012,sell to Africa(11.00%),Mid East(11.00%),Southeast Asia(10.00%),Domestic
Market(8.00%),South Asia(7.00%),Eastern Asia(7.00%),North America(7.00%),South America(7.00%),Central America(7.00%),Eastern
Europe(6.00%),Oceania(5.00%),Western Europe(5.00%),Southern Europe(5.00%),Northern Europe(4.00%). There are total about 11-50
people in our office.
2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.what can you buy from us?
Transformer Oil Purifier, Lubricating Oil Purifier, Oil Purification And Decoloration Machine, Cooking Oil Purification Machine,
Petroleum Products General Testers
4. why should you buy from us not from other suppliers?
Chongqing TOP Oil Purifier Co.,Ltd is a leading professional manufacture of oil purifiers from China. We practiced in this line
for more than 20 years and grown to be a full skilled team in tech research, operating, producing with rich experience.
5. what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,CIP,FCA,DDP,DDU,Express Delivery,DAF;
Accepted Payment Currency:USD,EUR,JPY,CAD,AUD,HKD,GBP,CNY,CHF;
Accepted Payment Type: T/T,L/C,Escrow;
Language Spoken:English,Chinese,Spanish,Portuguese,German,Arabic,French
WELCOME YOUR INQUIRY