Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
TP1200 Fog meter (general type) can easily realize ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, fog degree test, open sample bin can be erected, horizontal test, to adapt to more tested samples. TP1200 The fog meter uses PD array detector to meet the CIEV (λ) 2 degree visual response, compensation method measurement can achieve high precision and reproducible transmittance and fog data measurement.
Meet the ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, fog degree test, to provide more accurate test results.
5, convenient measurement, samples adapted to wide
Open measurement area, can be erected, horizontal test, adapt to more tested samples
6. Quality management software
Provide powerful fog, transmittance measurement and analysis software, suitable for various industry quality monitoring and haze and transmittance data tabular management. The user management is based on the PC computer to compare the difference of fog and light transmittance, and the test report form is generated to facilitate customer customization and management.
Model | TP1200 |
lighting method | Penetrance: 0/D(Parallel light illumination, and diffuse reflection reception) Standard:ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 |
characteristic | The instrument can easily realize ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, fog degree test. Open measurement area, can be erect, horizontal test. In glass processing, plastic processing, film, display processing, packaging industry and other industries of the transmittance, fog detection are widely used. |
Points ball size | Φ154mm |
Lighting light source | 700 nm from 400 |
Divide the way | / |
inductor | PD array detector meets the CIEV (λ) 2 degree visual response |
The wavelength range was measured | / |
wavelength interval | / |
half-band width | / |
Range of thetransmittancemeasurement | 0~100% |
Measuring the aperture | Φ20mm/Φ15mm/Φ8mm/Φ4mm() |
sample size | The thickness is less than170mm |
color space | / |
Color difference formula | / |
Other chromatic indicators | Haze (ASTM D1003/1044, ISO 13468), light transmittance T (ISO), light transmittance T (ASTM) |
Observer Angle | 2° |
Observational light source | D65,A,C |
display | Qualified / nonconforming results |
MT | About 1.5s |
resolution | Unit 0.01 |
repeatability | Φ20mm caliber, less than 0.05 (after the instrument is preheated and calibrated, test the standard haze sheet with a haze of about 30 at intervals of 5s for 30 times of standard deviation) |
Between the table difference | Φ20mm caliber, less than 0.4 (after the instrument is preheated and calibrated, test the standard deviation of the haze standard haze sheet and the reference value at an interval of 5s) |
Size | 290X211X511mm |
Weight | About 7.6kg |
Power Supply | DC 24V, 3A power adapter power supply |
Lighting light source life | More than 3 million measurements over 5 years |
display screen | TFT True color 7inch, capacitive touch screen |
interface | USB, print the serial port |
storage | 1000 standard samples and 20000 test samples |
Language | Simplified Chinese, Traditional Chinese, English |
operating temperature range (OTR) | 0~40ºC(32~104°F) |
Storage temperature range | -20~50ºC(-4~122°F) |
standard accessory | Power adapter, instruction manual, quality management software (download on official website), data line, 0% correction box, measuring diameter |
Optional attachment | Micro printer, test fixture, standard fog degree sheet, foot switch |
Note | Subject to change without prior notice |