SHATOX Portable Octane and Cetane Number Analyzer Model SX-300
Product Show:
Product description
Whether in the field or in the laboratory,this analyzers are leaders in portable rapid analysis instruments. We designs and produces analytical instruments for gasoline, diesel, motor oil and transformer oil.
Portable octane and cetane analyzers are often used for on-site analysis of octane number of power gasoline, corresponding to the motor method and research method (RON and MON), and also suitable for cetane number analysis of diesel. In addition, the temperature of the analyzed liquid and the freezing point of diesel can also be measured, and the measurement results are displayed on the LCD liquid crystal display.
Octane and cetane analyzer is widely used all over the world. Its measurement method conforms to international standards: octane measurement conforms to: ASTM D 2699-86, ASTM D 2700-86; diesel cetane measurement conforms to: ASTM D 4737- 03, ASTM D 613, EN ISO 5165.
Function
1. Determining octane numbers for motor petrols;
2. Determining cetane numbers for diesel fuels;
3. Determining solidification temperature and diesel fuel type;
4. Content of antiknock compounds boosting the octane number of petrols;
5. Content of pour-point depressants for diesel fuels;
6. Content of kerosine in summer diesel fuel;
7. Petrol breakdown time (oxidative stability);
8. Loss angle tangent of circuit-breaker, machine and engine oil;
9. Level of engine, machine and circuit-breaker oil clarity;
10. Manufacturer, engine oil brand;
11. Engine oil base number;
12. Dielectric permeability of oil products;
13. Oil products volume resistivity;
14. Determining the mechanical impurities content in oil products;
15. Determining the cut. GOST 14203-69 - Oil and oil products. Dielectric humidity measuring method.
Measuring principle
The principle of Octane Meter operation is in determining knock characteristic of gasoline, self-flammability of diesel fuel and in determining oil characteristics based on measurements of its dielectric permeability and volume resistivity.
Technical Specifications
# |
Parameter description |
Measurement units |
Value |
1 |
Measured petrols octane numbers range |
ON |
40-135 |
2 |
Acceptable limit of octane number measurement basic error, max |
ON |
±0.5 |
3 |
Limit of acceptable difference between parallel octane number measurements, max |
ON |
±0.2 |
4 |
The determination range of antiknock additives content in petrols |
% |
0.5-15 |
5 |
Acceptable basic error limit of antiknock additives content determination in petrols |
% |
0.1 |
6 |
Petrol oxidation breakdown time measurement range |
Min |
50-2400 |
7 |
Acceptable basic error limit of petrol oxidation breakdown time |
% |
5 |
8 |
Petrol quality determination mode basing on volume resistivity |
Ohm |
10 6-10 14 |
9 |
Acceptable basic error limit of volume resistivity measurements |
% |
3 |
10 |
Cetane numbers measurement range |
CN |
20-100 |
11 |
Acceptable basic error limit of cetane numbers, max |
CN |
±1.0 |
12 |
Acceptable difference limit between cetane numbers parallel measurements, max |
CN |
± 0.5 |
13 |
Acceptable error limit when determining diesel-fuel pour point |
ºC |
2 |
14 |
Kerosine content determination range in summer diesel fuels |
% |
0-50 |
15 |
Acceptable basic error limit when determining kerosene content in diesel fuels |
% |
3 |
16 |
Mode for pour point depressants content determination for diesel fuel |
% |
0.2-1 |
17 |
Acceptable basic error limit when determining of pour point depressants content |
% |
0.01 |
18 |
Motor oils clarity level measurement range |
% |
50-100 |
19 |
Acceptable error limit of motor oils clarity level measurement |
% |
0.1 |
20 |
Acceptable difference limit between motor oils clarity parallel measurements |
% |
0.01 |
21 |
POL dielectric permeability measurement range |
units |
1-5 |
22 |
Acceptable error limit of dielectric permeability measurement, max |
unit |
0.001 |
23 |
Acceptable difference limit between POL dielectric permeability parallel measurements, max |
unit |
0.001 |
24 |
Oils base number determination range |
unit |
3-24 |
25 |
Acceptable basic error limit when determining oils basic number |
BN unit |
1 |
26 |
Motor oils manufacturer and brand determination |
Manufacturer |
- |
27 |
Circuit-breaker oils (dielectrics) breakdown voltage measurement range |
kV |
5-100 |
28 |
Acceptable error limit of circuit-breaker oils breakdown voltage measurement, max |
kV |
1 |
29 |
Acceptable difference limit between circuit-breaker oils breakdown time parallel measurements, max |
kV |
0.2 |
30 |
Measurement range of circuit-breaker oils loss angle tangent |
% |
0.01-40 |
31 |
Acceptable error limit of circuit-breaker oils loss angle tangent, max |
% |
0.01 |
32 |
Acceptable difference limit between circuit-breaker oils loss angle tangent parallel measurements, max |
units |
0.001 |
33 |
Determination range for mechanical impurities content in oil products |
% |
97-100 |
34 |
Acceptable basic error limit when determining mechanical impurities content in oil products |
% |
0.01 |
35 |
Water-in-oil content determination range for oil products |
% |
0-30 |
36 |
Acceptable basic error limit when determining water-in-oil content of oil products |
% |
1 |
37 |
Measurement time |
sec |
1-5 |
38 |
Insufficient power supply indication operation threshold |
V |
5.4 |
39 |
Instrument useful life |
|
6 |
40 |
Overall dimensions of: |
|
|
|
electronic module |
mm |
100х210х40 |
|
sensor #1 and #2 |
mm |
60х100 |
|
Instrument mass with one sensor/two sensors |
g |
850 / 680 |
About Us
Located at Chongqing city--a southwest electromechanical manufacturing center as well as national municipality, Chongqing TOP is a professional leading manufacturer and supplier of oil purifiers and various related testers. Our company consists of departments respectively for technological development, machinery manufacture, instrument manufacture and quality control etc. On basis of mature development and manufacture technology and highly qualified production management team, the products have high quality, easy operation, excellent performance and long service life.
TOP Oil Purifiers are widespread in the fields of electric power, petrifaction, mineral, shipbuilding, steel construction, bridge, automobile and railway. They play a great role in reducing energy consumption for clients as well as environmental pollution. We provide you with reliable oil purifiers such as transformer oil purifier, turbine oil purification machine, hydraulic oil purifier, lubricating oil filtration machine, fuel oil restoration, oil and water separator, oil regeneration equipment, and waste oil recycling equipment etc.
TOP Testers work on the development, production, market, technical and after-sale service for petrochemical analyzers, transformer substation electrical testing equipment and circuit detecting equipment. Main products are water content testers, surface/interfacial tension testers, flash point testers, kinematic viscosity testers, oil acidity testers, insulation oil dielectric strength testers, transformer characteristics testers, relay protection testers,and high voltage testing equipment etc.
Our Main Testers
1.Fully Automatic Karl Fischer Water Content Tester TP-2100
2.Kinematic Viscosity Tester VST-2000
3. Fully Automatic Oil Acidity Tester (6 cups) ACD-3000I
4. Fully Automatic Surface/Interface Tension Tester IT-800
5. Fully Automatic Open Cup Flash Point Tester TPO-3000
6.Fully Automatic Closed Cup Flash Point Tester TPC-3000
7.Cloud Point & Pour Point Tester PT-2000
8.Multi-functional Vibration Tester VBT-2000
9.Petroleum Products Density Tester DST-3000
10.Distillation Range Tester DIL-201
11.Liquid Phase Corrosion Tester TPS-05
12.Copper Corrosion Tester TP-113
13.Petroleum And Synthetic Liquid Anti-Emulsification Tester TP-122
14.Dew Point Tester DPME-P
15.Vehicle Gear Oil Channel Point Tester Model TP-0030
16.Anti-Corrosive Oil/Grease Salt Spray Corrosion Tester Model TP-0081
17. Mechanical Impurities Tester Model PC-511
18. Air Release Value Tester Model TP-0308
19.Distillate Fuel Oil Oxidation Stability Tester Model TP-175
20. Foam Characteristics Tester Model FC-892
21.Dark Petroleum Products Sulfur Content Tester Model TPC-120
22. Petroleum Products Aniline Point Tester Model TP-262A
23.Petroleum Products Ash Tester Model TP-508
24.Petroleum Products Chroma Tester Model TP-225
25. Automatic Petroleum Products Carbon Residue Tester (Micromethod) CS-0625
26.Spontaneous Ignition Point Tester FP-706
27.Fully Automatic Glassware Washing Machine TP504
28. Lube Oil/Grease Evaporation Loss Tester EL-7325
29. Crude Oil And Fuel Oil Sediment Tester TP-130
30. Wide Temperature Range Lubricating Grease Drop Point Tester TLS-22
31. Crude Oil And Petroleum Products Salt Content Tester SCA-068
32. Petroleum Products Saturated Vapor Pressure Tester(Reid Method) TP-8017
33.Petroleum Products Freezing Point Tester TP-2430
34. Oxygen Bomb Calorimeter TP-1B
35. Existent Gum Tester TP-509A
36.Octane and Hexadecane Value Tester TP-131
37.Automatic Gasoline Oxidation Stability Tester TP-148
38. Light Petroleum Products Sulfur Content Tester (Lamp-Kindled Method) TP-119
39. Resistant oil Chlorine Content Tester TP388
40. Distillate Fuel Mercaptan Sulfur Tester TP-624
Service Commitment1. Long-term warranty of 2 years.
2. Provide best necessary spare parts at low price (some for free).
3. Provide timely reply and technical support within 24 hours.
4. OEM is available for TOP Products.
5. Protect your sales area, ideas of design and all your private information.
Safe and Timely Transportation
*Standard export wooden case with high quality cushioning material ensures that the customers get the item in good condition.
*Carefully check every packing detail before delivery to avoid any troubles during the transportation.
*Appointed logistics company could be used according to customers demands.
* Do our best to make sure customers can get their goods in time.