Ptt-2000zde Intelligent Laser Particle Size Analyzer

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)
  • Ptt-2000zde Intelligent Laser Particle Size Analyzer
  • Ptt-2000zde Intelligent Laser Particle Size Analyzer
  • Ptt-2000zde Intelligent Laser Particle Size Analyzer
  • Ptt-2000zde Intelligent Laser Particle Size Analyzer
  • Ptt-2000zde Intelligent Laser Particle Size Analyzer
  • Ptt-2000zde Intelligent Laser Particle Size Analyzer
Find Similar Products

Basic Info.

Model NO.
PTT-2000ZDE
Principle
Mie Scattering Principle
Channels Number
39 PCS
Test Speed
<2mins for Each Time
Transport Package
International Standard Export Case
Specification
CE/ISO
Trademark
TOP Tester
Origin
China
HS Code
9031809090
Production Capacity
200 Sets/Month

Product Description

TP-2000ZDE Intelligent Laser Particle Size Analyzer
 
 
Ptt-2000zde Intelligent Laser Particle Size Analyzer

Overview:
TP-2000ZDE intelligent laser particle size analyzer, perform auto test, auto alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion, auto cleaning etc., really realize one-key operation. It adopt full built-in sampling system, effectively prevents large particles sedimentation problems in the circulation pipeline, ensure good accuracy. It adopts comprehensive Laser diffraction particle size measurement principle with highly sensitive ring photoelectric detector improving the test accuracy greatly, Original designed unconstrained free fitting software technology, a true reflection of the particle size distribution, to ensure truth and accuracy of the test results. Therefore especially suits the laboratories of enterprises, colleges and universities and research institutes to use.

Main Specifications:
Model Name TP-2000ZDE
Standard ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009
Principle MIE scattering principle
Measuring Range 0.1μm-300μm
Channels Number 39 PCS
Accuracy error <1%   ( CRM D50 )
Repeatability error <1%   ( CRM D50 )
Light source High performance He-Ne Laser (λ= 632.8nm,  P>2MW)
Lifetime>25000hour

Dispersion
 Method
Ultrasonic Frequency:40KHz   Power:50W,   Time: ≥1S
Stir Revolutions Speed: 0-3000RPM (Adjustable)
Circulate Rated Flow:8L/min    Rated Power:10W
Sample Pool Volume:350mL
Micro-
Sample Pool
Volume: 10mL ( Available)
Operation Mode Full automatic and manual control, freely choose
Output parameter D10,D50,D90,D100,S/V referent parameters
Optical Calibration System Full automatic
Test Speed <2mins for each time
Volume L88cm×W39cm×H46cm
Net Weight 41Kg


Main Features:
  1. Advanced design of optical path: 
A patented technique of Fourier transform of converging light released the scattered light at large-scattering-angles from the restriction of the aperture of the Fourier lens. The focal length is reduced to enhance the resolution of the instrument, and ring shaped of  multi-element silicon photo-diode ensure gathering all the light signals of particles, highly improve the resolution.
  1. Built-in automatic wet dispersion unit: 
We carefully aligned the stirring set-up, the ultrasonic dispersing unit and the sample circulation pipes, and fixed them inside the instrument. Such a built-in design effectively prevents the inhomogeneous dispersion and sedimentation of big particles, which can be observed in the designs that these dispersing units are separated from the instruments, where the sample circulation pipes are therefore too long, The sample will be sufficiently dispersed.
  1. Unconstrained fitting techniques: 
The particle analysis software uses a unique unconstrained data fitting technique that we developed to obtain data of real particle size distribution, this is particularly important for researchers.
  1. Micro sample chamber (optional):
 The capacity of the sample chamber is as small as only 10ml. This helps with measuring expensive/precious samples, or samples difficult to be dispersed within medium.
  1. Modern measurement control:(Intelligent SOP Operation)
 Users can perform all measurement procedures by simply operating on the PC and have ideal results in a very short time.
  1. User-friendly Operation:  
manual mode and the automatic mode, freely choose, to measure according to the sample features. In some conditions (e.g. the sample have unknown features or there are special requirements for the measurements), users can make a test measurement in the manual mode first, and after having an idea of the sample features and the measurement conditions, measure the samples in the automatic mode.
  1. Fully automatic light path alignment: 
A precise four phase hybrid stepping motor automatically aligns the optical path and can adjust it at any moment, precision is up to 0.1um, This releases users from manual adjusting the optical path and improved accuracy and stability of the measurement results.
  1. Quick measurements: 
set " automatic" mode, all operation procedures are performed automatically,automatic water supply, automatic ultrasonic sample, stirring, circulation,background testing, sample testing,analysis , draining and cleaning, which significantly reduces the time for measurements, the full process only take 2 minutes.
  1. Data analysis: 
Errors in the data are rejected and the measurement results are automatically processed. Manual data processing is not necessary and the output is more standard. 


Software Function
  1. Analysis Mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. meet different demands of particle size statistic in different industries.
  1. Statistic Method
Volume Distribution, Quantity Distribution
  1. Statistic Comparison
Statistic Several Testing Results to compare and analyze
Get difference by compare test result of different batches of samples, samples  before and after processing, and different time.
Have great practical significance to industrial raw materials quality control
  1. User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries.
  1. Test Report
Word, Excel,Photo( Bmp), Text etc.
  1. Multiple language Support
Chinese&English (Others are available)
  1. Intelligent Operation Mode
Automatically control water inflow, dispersion,test and analysis.
Better Repeatability after remove human-factor

Laser Particle Size Analyzer Application Field:
 
  1. Non-metallic powders such as calcium carbonate, talcum powder, kaolin, zirconium silicate, wollastonite, graphite, silica powder, tourmaline, mica, barite, plaster, bentonite, diamond, quartz, diatomite, feldspar, calamite,clay, garnet, vermiculite, Titanium white power, etc.
  2. Metallic powder such as aluminum powder, iron powder, magnesium powder, molybdenum powder, copper powder, zinc powder, other rare metal power and varied alloy powder, etc.
  3. Pharmaceutical, agricultural pesticide, grinding particle, foodstuff, scientific research, teaching, cement, ceramic, glass, chemical industry, military industry, soil, toner,pigment, oil exploration, geological analysis, river silt and electronic particle, etc.

TP-2000ZDE Laser Particle Size Analyzer Patents Technology:
  1. Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
  2. Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
  3. MIE scattering principle application patent is protected by patent No.- ZL 2013 2 0812021.4.
  4. Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2.

Report Interpretation
  1. D10=X, means ≤X particle size's particle volume content occupy 10% of all the particles.
  2. D50=Y, means ≤Y particle size's particle volume content occupy 50% of all the particles.
  3. D90=Z, means ≤Z particle size's particle volume content occupy 90% of all the particles.
  4. DAV: Average particle size of particles group
  5. S/V: Specific surface area, surface to volume ratio/ Surface area per unit volume
  6. D[3,2] Weighted average surface area
  7. D[4,3] Volume weighted average
  8. Particle Size Analysis Chart illustration:
  • The transverse is the particle size value, and the value is logarithmic distribution.
  • The left column is the volume of the cumulative percentage, the corresponding curve is upward trend.
  • The right column is the percentage of the volume of a certain interval, corresponding to the histogram or undulating curve.
  • The data list is corresponding to the test result of analysis chart.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier