Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The desktop spectrophotometer TP8296 is a spectrophotometer developed by using independent spectroscopic core technology. It adopts a dual-array CMOS image sensor with high sensitivity and wide spectral response range, and the test is more accurate. TP8296 desktop spectrophotometer can easily control the repeatability △E*ab within 0.01, and the inter-stage difference △E*ab within 0.12. The data is stable and reliable, and can be used for accurate analysis and transmission of colors in laboratories.
1.It adopts the internationally accepted D/8 structure, is compatible with SCI/SCE measurement, and supports SCI+SCE simultaneous fast measurement.
TP8296 desktop spectrophotometer adopts D/8 illumination observation conditions widely applicable in the world, SCI/SCE (including specular reflection/not including specular reflection) synthesis technology, and supports SCI+SCE simultaneous rapid measurement.
2.Dual-array CMOS image sensor
It has high sensitivity and wide spectral response range, which ensures the measurement speed, accuracy, stability and consistency of the instrument.
3.A variety of color measurement space, a variety of observation light sources.
TP8296 Desktop Spectrophotometer provides CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN Lab99 color space, and D65, A, C, D50, D55, D75, F1, F2 , F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, DLF, TL83, TL84, TPL5, U30 various observation light sources, which can meet the special measurement requirements under different measurement conditions.
4.The combined full-spectrum LED light source, and the UV light source were used
The full band balanced LED light source ensures that there is sufficient spectral distribution in the visible range, avoids the white LED and the spectrum of a specific band, and ensures the instrument measurement speed and the accuracy of the measurement results. The professional UV light source ensures that the UV test is more reliable.
5.Measurement verification report
Each TP8296 Desktop Spectrocolorometer has been verified and tested, and the instruments are verified according to the measurement standards of the authoritative verification department. The measurement data are traceable to the National Metrology Institute to ensure the authority of the instrument test data.
6.Automatic recognition of caliber
TP8296 Desktop Spectroscopic colorometer equipped with φ 25.4/15/8/4mm four measuring diameter, can be arbitrary switch to take into account the special needs of customers.
7.Industrial-grade hd touch screen, simple and easy to use user interface
The 7-inch industrial HD touch screen, smooth control, easy to use user interface makes the operation comfortable, convenient and easier to use.
8. Color management software
The SQCX quality management software matched with the TP8296 desktop spectrophotometer is suitable for quality monitoring and color data management in various industries. Dataize the user's color management, compare color differences, generate test reports, provide a variety of color space measurement data, and customize the customer's color management work.
Model :TP8296 |
lighting system :Reflection: D / 8 (diffuse illumination, 8-direction reception); SCI / SCE measurement; including UV / excluded UV measurement; Transmission: D / 0 (diffuse illumination, 0-direction reception); SCI / SCE measurement; including UV / exclusion UV measurement; fog degree (ASTM D1003); |
Standard :CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7 Integral sphere dimensions :φ154mm Lighting and light source :360~780nm combined LED light source, 400nm cut-off source and 420nm cut-off source |
Light ting mode :concave grating inductor :256 Image element dual-array CMOS image sensor |
The wavelength range was measured:360~780nm |
wavelength interval:10nm |
half-band width :5nm |
Range of the reflectance determination:0~200% Measurement diameter: reflection: φ 30mm / φ 25.4mm, φ 18mm / medium 15mm, φ 10mm / φ 8mm, φ 6mm / φ 4mm; transmission: φ 25.4mm / φ 4mm Note: 1. Automatic identification of switching diameter; 2. Customers can configure the diameter and lens position as required |
Light mode:Reflection SCI / SCE, transmitted SCI / SCE |
color space:CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
Color difference formula: △E*ab,△E*uv,△E*94,△E*cmc(2:1),△E*cmc(1:1),△E*00,DIN△E99,△E(Hunter) Other color metrics: WI (ASTM E313, CIE / ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), isochromatic index Mt, color fastness, color fastness, force, covering, APHA / Hazen / Pt-Co (platinum cobalt index), Gardner index, 8 degree gloss, 555 tone classification, Fog degree (ASTM D1003), Saybolt (Seibert index), ASTM D1500 color standard, Chinese Pharmacopoeia color standard |
Observer Angle:2°/10 |
Observational light source: D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 Display:Spectrum map / data, sample color degree value, color difference value / figure, color product map, color simulation, qualified / unqualified results, color bias |
MT:About 2.4s(Testing test SCI / SCE about 5s) |
repetitiveness : Spectral reflectance: φ25.4mm/SCI, within the standard deviation of 0.04% chromatic value:φ25.4mm/SCI, Within △ E * ab, 0.01 (whiteboard 30 mean measurements at 5s interval after instrument preheating correction) Divide through the rate:φ25.4mm/SCI, standard deviation within 0.05% chromatic value :φ25.4mm/SCl,△E*ab Within 0.02 (average 30 times at 5s intervals) Between the table difference :Middle25.4mm/SCI,△E*ab Within 0.12 (mean average of 12 BCRA series) Size:370X300X200mm |
Weight :About9.6kg |
Power supply:DC 24V, 3A power adapter power supply |
Lighting light source life:More than 3 million measurements over 5 years display screen :TFT True color 7inch, capacitive touch screen interface:USB,Print the serial port, Bluetooth |
Storage:5000 standard specimens and 40000 test specimens (SCI / SCE count as one data) |
Language :Simplified Chinese, Traditional Chinese, English, (customized in German, French, Spanish) standard attachment:Power adapter, instruction manual, quality management software (official website download), data line, standard correction board, black correction box, black transmission black baffle, sample holder, 25.4mm diameter, 15mm diameter, 8mm diameter, 4mm diameter, transmission test fixture assembly, microhole (4mm) transmission test fixture assembly Optional attachment:Micro printer, instrument inverted test fixture, Petri dish |