Gas Oil Analyzer Portable Tester Model Sx-300

Product Details
Customization: Available
Measured Petrols Octane Numbers Range: 40-135
Acceptable Limit of Octane Number Measur: ±0.5
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)
  • Gas Oil Analyzer Portable Tester Model Sx-300
  • Gas Oil Analyzer Portable Tester Model Sx-300
  • Gas Oil Analyzer Portable Tester Model Sx-300
  • Gas Oil Analyzer Portable Tester Model Sx-300
Find Similar Products

Basic Info.

Model NO.
SX-300
Petrol Oxidation Breakdown Time Measurem
50-2400min
Cetane Numbers Measurement Range
20-100
Acceptable Error Limit When Determining
2ºC
Kerosine Content Determination Range in
0-50%
Pol Dielectric Permeability Measurement
1-5 Units
Oils Base Number Determination Range
3-24 Units
Circuit-Breaker Oils (Dielectrics) Break
5–100 Kv
Transport Package
Standard Export Wooden Case
Specification
Customizable
Trademark
TOP Tester
Origin
Chongqing, China
HS Code
9030899090
Production Capacity
100 Sets Per Month

Product Description

Gas Oil Analyzer Portable Tester Model SX-300

Gas Oil Analyzer Portable Tester Model Sx-300Whether in the field or in the laboratory,this analyzers are leaders in portable rapid analysis instruments. We designs and produces analytical instruments for gasoline, diesel, motor oil and transformer oil.

Portable octane and cetane analyzers are often used for on-site analysis of octane number of power gasoline, corresponding to the motor method and research method (RON and MON), and also suitable for cetane number analysis of diesel. In addition, the temperature of the analyzed liquid and the freezing point of diesel can also be measured, and the measurement results are displayed on the LCD liquid crystal display.

Octane and cetane analyzer is widely used all over the world. Its measurement method conforms to international standards: octane measurement conforms to: ASTM D 2699-86, ASTM D 2700-86; diesel cetane measurement conforms to: ASTM D 4737- 03, ASTM D 613, EN ISO 5165.



Gas Oil Analyzer Portable Tester Model Sx-300
  1. Determining octane numbers for motor petrols;
  2. Determining cetane numbers for diesel fuels;
  3. Determining solidification temperature and diesel fuel type;
  4. Content of antiknock compounds boosting the octane number of petrols;
  5. Content of pour-point depressants for diesel fuels;
  6. Content of kerosine in summer diesel fuel;
  7. Petrol breakdown time (oxidative stability);
  8. Loss angle tangent of circuit-breaker, machine and engine oil;
  9. Level of engine, machine and circuit-breaker oil clarity;
  10. Manufacturer, engine oil brand;
  11. Engine oil base number;
  12. Dielectric permeability of oil products;
  13. Oil products volume resistivity;
  14. Determining the mechanical impurities content in oil products;
  15. Determining the cut. GOST 14203-69 - Oil and oil products. Dielectric humidity measuring method.

 Gas Oil Analyzer Portable Tester Model Sx-300                
# Parameter description Measurement units Value
1 Measured petrols octane numbers range ON 40-135
2 Acceptable limit of octane number measurement basic error, max ON ±0.5
3 Limit of acceptable difference between parallel octane number measurements, max ON ±0.2
4 The determination range of antiknock additives content in petrols % 0.5-15
5 Acceptable basic error limit of antiknock additives content determination in petrols % 0.1
6 Petrol oxidation breakdown time measurement range Min 50-2400
7 Acceptable basic error limit of petrol oxidation breakdown time % 5
8 Petrol quality determination mode basing on volume resistivity
Ohm
10 6-10 14
9 Acceptable basic error limit of volume resistivity measurements
%
3
10 Cetane numbers measurement range CN 20-100
11 Acceptable basic error limit of cetane numbers, max CN ±1.0
12 Acceptable difference limit between cetane numbers parallel measurements, max
CN

± 0.5
13 Acceptable error limit when determining diesel-fuel pour point ºC 2
14 Kerosine content determination range in summer diesel fuels % 0-50
15 Acceptable basic error limit when determining kerosene content in diesel fuels
%

3
16 Mode for pour point depressants content determination for diesel fuel % 0.2-1
17 Acceptable basic error limit when determining of pour point depressants content % 0.01
18 Motor oils clarity level measurement range % 50-100
19 Acceptable error limit of motor oils clarity level measurement % 0.1
20 Acceptable difference limit between motor oils clarity parallel measurements % 0.01
21 POL dielectric permeability measurement range units 1-5
22 Acceptable error limit of dielectric permeability measurement, max unit 0.001
23 Acceptable difference limit between POL dielectric permeability parallel measurements, max unit 0.001
24 Oils base number determination range unit 3-24
25 Acceptable basic error limit when determining oils basic number BN unit 1
26 Motor oils manufacturer and brand determination Manufacturer -
27 Circuit-breaker oils (dielectrics) breakdown voltage measurement range kV 5-100
28 Acceptable error limit of circuit-breaker oils breakdown voltage measurement, max kV 1
29 Acceptable difference limit between circuit-breaker oils breakdown time parallel measurements, max kV 0.2
30 Measurement range of circuit-breaker oils loss angle tangent % 0.01-40
31 Acceptable error limit of circuit-breaker oils loss angle tangent, max % 0.01
32 Acceptable difference limit between circuit-breaker oils loss angle tangent parallel measurements, max units 0.001
33 Determination range for mechanical impurities content in oil products % 97-100
34 Acceptable basic error limit when determining mechanical impurities content in oil products % 0.01
35 Water-in-oil content determination range for oil products % 0-30
36 Acceptable basic error limit when determining water-in-oil content of oil products % 1
37 Measurement time sec 1-5
38 Insufficient power supply indication operation threshold V 5.4
39 Instrument useful life   6
40 Overall dimensions of:    
  electronic module mm 100х210х40
  sensor #1 and #2 mm 60х100
  Instrument mass with one sensor/two sensors g 850 / 680
                                                                                             
Gas Oil Analyzer Portable Tester Model Sx-300
Gas Oil Analyzer Portable Tester Model Sx-300Gas Oil Analyzer Portable Tester Model Sx-300Gas Oil Analyzer Portable Tester Model Sx-300
Gas Oil Analyzer Portable Tester Model Sx-300
 
MOQ 1 Set
Trade Terms EXW, FOB, CIF, CFR
Payment Terms T/T, L/C
Port of Loading Any Port of China
Packing Method Internaional Standard Wooden Case
Transportation Method By Sea, By Land, By Air, By Express
Supply Capability 100 Sets/Month

Gas Oil Analyzer Portable Tester Model Sx-300Gas Oil Analyzer Portable Tester Model Sx-300

 

Gas Oil Analyzer Portable Tester Model Sx-300Gas Oil Analyzer Portable Tester Model Sx-300

Gas Oil Analyzer Portable Tester Model Sx-300Gas Oil Analyzer Portable Tester Model Sx-300

☎ Exhibition

Gas Oil Analyzer Portable Tester Model Sx-300

Welcome to visit our website, welcome your inquiry.

Welcome to visit our website, welcome your inquiry.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier