ASTM D971 Surface/ Interface Tensiometer for Liquid It-800p Series

After-sales Service: 1 Year
Warranty: 1 Year
Test Method*: Plate Method & Ring Method
Operation Method: Automatic Lifting and Lowering of Sample Stage Aut
Lifting Speed: 0~300mm/Min Arbitrarily Adjustable
Temperature Measurement: -40ºC~250ºC
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Chongqing, China
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)

Basic Info.

Model NO.
IT-800P-2000& 1000& 500
Display Method
7-Inch Touch Screen, Data Read Directly
Data Method
Support Data Storage/View/Print
Measure Time
Normally Within 60 Seconds
Transport Package
International Export Standard Case
Specification
700*550*700mm
Trademark
TOP TESTER
Origin
Chongqing
HS Code
9031809090
Production Capacity
100 Sets/Month

Product Description

ASTM D971 Surface/ Interface Tensiometer Tension Tester for Liquid
IT-800P Series
ASTM D971 Surface/ Interface Tensiometer for Liquid It-800p SeriesFlexible and versatile surface/interfacial tension measurement methods
tensiometer provides many expansion modules to expand the application scope of the instrument, which is used to measure various characteristics of surfaces and interfaces, which greatly improves the flexibility of its use. The main measurement principle is to accurately obtain the force between the measurement accessory or the sample to be measured when it is wetted by liquid. The instrument uses standard methods including the DuNoüy ring method and the Wilhelmy plate method. to measure the surface and interfacial tension of liquids. In addition, the instrument can be used to accurately measure the density of liquids with the necessary optional accessories.
The spacious sample room is equipped with a transparent glass sliding door, which can protect the room from disturbed airflow. A built-in electronic level aids in precise adjustment of the sample stage for precise force measurement.
The built-in measurement program can control the sample stage to ensure that there is no human interference in the measurement process. The running speed can be adjusted according to the experimental requirements and can be accurately repeated. The use of a dynamic, smooth-running drive eliminates negative vibrations. In addition, the long-term drift of the mechanical sensor is minimized.
Through the 7-inch touch screen, simple and intuitive operation is realized. Intuitive operation on the touch screen is a feature of the new generation of tensiometers, allowing easy control of the sample stage and other components before and during a measurement.
Built-in measurement data management menu, easy to view data and support external printer operation. All measurement data files can be transferred through a USB flash drive to convert to Excel files for easy management, recording and organization of measurement data.
The machine program has a password management function to ensure that the data can be traced and prevent data modification and accidental deletion.

Standards:
We attach great importance to the repeatability and standardization of measurement results, and the Q series tensiometers are designed to comply with all GB/T, EU, ISO, DIN and ASTM standards for surface and interfacial tension.
Satisfies partially valid norms and standards
ASTM D971 Standard Test Method for Oil-Water Interfacial Tension Using the Lifting Ring Method
ASTM D1331 Standard Test Method for Surface and Interfacial Tension of Surfactant Solutions
ASTM D1417 Standard Method for Testing Synthetic Rubber Latex
DIN EN 14210 Surfactants - Determination of the interfacial tension of surfactant solutions by the stirrup or ring method
DIN EN 14370 Surfactants - Determination of surface tension
ISO 6889 Surfactants - Determination of surface tension by the pull-film method

ISO 304 Surfactants - Determination of Surface Tension by the Pull-Film Method
ISO 1409 Plastics/rubber - Polymer dispersions and rubber latexes (natural and synthetic) - Determination of surface tension by the ring method


Product Specification:
Model IT-800P-2000 IT-800P-1000 IT-800P-500
Test method*  Plate method & Ring method
Surface Tension Test Range 0-2000mN/m 0-1000mN/m 0-500mN/m
Surface Tension Accuracy 0.1mN/m 0.01mN/m 0.001mN/m
Density range** 0-3.000g/cm3 N/A
Density Accuracy** 0.001g/cm3 N/A
Operation method Automatic lifting and lowering of sample stage Automatic measurement
Lifting speed 0-300mm/min   Arbitrarily Adjustable
Temperature measurement -40ºC-250ºC(Optional PT100 temperature sensor)
Display method 7-inch touch screen, data read directly
Data method Support data storage/view/print
Measure time Normally within 60 seconds
Data output** RS232 (printer) or U disk
Data software Includes ST Flash software
Size 47*24.5*47.5cm L*W*H
Level way Electronic level adjustment
Net Weight 18kg
Power 110V or220V,50W