• High Vacuum Transformer Oil Purifier for Purification of Electrical Insulating Liquids
  • High Vacuum Transformer Oil Purifier for Purification of Electrical Insulating Liquids
  • High Vacuum Transformer Oil Purifier for Purification of Electrical Insulating Liquids
  • High Vacuum Transformer Oil Purifier for Purification of Electrical Insulating Liquids
  • High Vacuum Transformer Oil Purifier for Purification of Electrical Insulating Liquids
  • High Vacuum Transformer Oil Purifier for Purification of Electrical Insulating Liquids

High Vacuum Transformer Oil Purifier for Purification of Electrical Insulating Liquids

Certification: CE
Application: Transformer Oil
Voltage: 380V
Folw Rate: 200 L/min
Oil Treated: Insulating Oils
Features: Oil Booster Pump for Hot Oil Spray
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Chongqing, China
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)

Basic Info.

Model NO.
ZYD-200
Features 1
Interstage Chilled Trap
Transport Package
Wooden Case
Specification
2000x1500x2100 mm
Trademark
TOP Oil Purifier
Origin
Chongqing, China
HS Code
84212990
Production Capacity
1000 Sets/Month

Product Description

Transformer Oil Purifiers

High Vacuum Oil Purifier & Transformer Dry-out System

High Vacuum Transformer Oil Purifier for Purification of Electrical Insulating Liquids
Model ZYD Series
Purification of Electrical Insulating Liquids
Today's state-of-the-art electrical equipment requires the need for a high degree of insulating fluid purification. Such requirements call for the removal of moisture, gases, solid particulate matter and traces of chemical contamination from the insulating fluid.
Moisture content is recognized as one of the main causes of variation in the electrical properties of insulating materials, both from a chemical and physical point of view. Even in small amounts, moisture can accelerate the aging process.
Under these circumstances, it is important to start initially at the factory with a dry insulation system and pure, dry and degasified dielectric liquid during transformer impregnation and the qualification tests. Later, the same care must be taken during installation in the field and after every maintenance check, requiring exposure of the insulating system to the environment.
The ZYD process, developed by TOP, upgrades new insulating liquids and reclaims used dielectric oils through filtration, vacuum dehydration, degasification and clay treatment (when necessary).

ZYD Systems include filters with a 0.5-1.0 micron nominal filtration rating for the removal of particulate. If excessive free water is present in oil, a free water trap is used prior to vacuum dehydration. The ZYD High Vacuum Process then removes dissolved water, free and absorbed air and other gases.

The ZYD Fuller's Earth Filters provide corrective treatment for removal of the products of oxidation, dissolved varnish and gums and other traces of chemical contaminants.

ZYD Systems with High Vacuum Pumps provide fast and complete transformer dry-out and fill with clean, dry and hot oil under vacuum conditions. ZYD Interstage Oil Condensers provide a continuous system for removal of light-end oils for vacuum system protection during transformer dry-out processes.

Product Type and Main Technical Parameter
Technical data ZYD-30 ZYD-50 ZYD -75 ZYD-100 ZYD -150 ZYD -200 ZYD -300 ZYD -500 ZYD -1000
Rated Flow rate (L/h) 1800 3000 4500 6000 9000 12000 18000 30000 60000
Heating Power (kw) 30 42 54 60 84 108 156 225 450
Total Power (kw) 33 46 60 67 94 119 173 257 511
Inlet(outlet) Dia.(mm) 25 32 40 40 50 50 65 80 100
Dimensions(cm) L 1380 1500 1750 1900 2100 2300 2600 3200 3600
W 1100 1200 1250 1280 1300 1300 1380 1500 1600
H 1600 1650 1650 1700 1800 1850 1950 2100 2300
Net Weight (kg) 600 800 900 1050 1500 1800 2200 3960 4980
Notice: Due to different type and components of product, the technical data may vary slightly.
Main Technical Data
Vacuum Range -0.07~-0.095MPa
Working Pressure 0.5MPa
Working Temperature 50~75ºC
Power Supply 50Hz 380V
Filtration fineness 1~5μm
Guarantee Performance Index
Insulation Oil Before Treatment After One Time Treatment After the Treatment of few Times
Water Content in the Oil 50PPm 15PPm 3~5PPm
Gas Content in the Oil 12% 0.5% 0.1%
Flash Point 135ºC ≥135ºC ≥135ºC
Breakdown Voltage≥35kv ≥55kv ≥60~75kv

High Vacuum Transformer Oil Purifier for Purification of Electrical Insulating LiquidsHigh Vacuum Transformer Oil Purifier for Purification of Electrical Insulating LiquidsHigh Vacuum Transformer Oil Purifier for Purification of Electrical Insulating Liquids
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now