Model | TP510T | |
Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
pH |
Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ± 0.002 pH | |
Calibration Points | Up to 8 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | USA, NIST, MERK, JIS, GB and DIN buffers | |
Slope Limit | Yes | |
mV/ORP |
Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ± 0. 1 mV or ± 0.03% | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1 custom point (relative mV) | |
pX |
Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ± 0.002 pX | |
Calibration Points | Up to 6 | |
ISE |
Range | 1E-9 to 9.999E9 |
Units | mol/L, mmol/L, g/L, mg/L, μ g/L | |
Resolution | Up to 4 significant digits | |
Accuracy | ± 0.3% | |
Calibration Points | Up to 8 | |
Conductivity |
Range | 0.000 μ S/cm to 3000 mS/cm |
Resolution | 0.001 μ S/cm minimum, various with range selection |
|
Accuracy | ± 0.5% FS | |
Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
Calibration Points | Up to 5 | |
Calibration Reminder | Yes | |
Standard Recognition | 10 μ S/cm, 84 μ S/cm, 500 μ S/cm, 1413 μ S/cm, 12.88mS/cm | |
Resistivity | Range | 5.00 Ω ·cm~100.00 M Ω ·cm |
Resolution | 0.01 Ω ·cm minimum | |
Accuracy | ± 0.5% FS | |
TDS | Range | 0.000mg/L~1000g/L |
Resolution | 0.001mg/L minimum, changed with range | |
Accuracy | ± 0.5% | |
Salinity | Range | (0.00~8.00)% |
Resolution | 0.01% | |
Accuracy | ± 0. 1% | |
Dissolved Oxygen Concentration |
Sensor Type | Polarographic |
Range | 0.00 to 99.99 mg/L | |
Resolution | 0.01mg/L | |
Accuracy | ± 0.3mg/L (0.00 to 20.00 mg/L); ± 10% (20.00 to 99.99 mg/L) | |
Calibration Reminder | Yes | |
Calibration Points | Air-saturated water or zero point | |
Barometric Compensation | Yes | |
Manual Salinity Factor Correction | Yes | |
Saturation | Range | (0.0 to 600.0)% |
Resolution | 0.10% | |
Accuracy | ± 10.0% | |
Temperature |
Range | - 10 to 135 ºC, 14 to 275 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Relative Accuracy | ± 0. 1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 1000 Groups |
GLP Features | Yes |