Product description
Portable octane analyzers are often used for on-site analysis of octane number of power gasoline, corresponding to the motor method and research method (RON and MON), and also suitable for cetane number analysis of diesel. In addition, the temperature of the analyzed liquid and the freezing point of diesel can also be measured, and the measurement results are displayed on the LCD liquid crystal display.
This octane analyzer is widely used all over the world. Its measurement method conforms to international standards: octane measurement conforms to: ASTM D 2699-86, ASTM D 2700-86. Diesel cetane measurement conforms to: ASTM D 4737- 03, ASTM D 613, EN ISO 5165.
Measuring principleThe principle of the TP-150 octane cetane number tester lies in the analysis of the insulation permeability of the octane number of gasoline and the cetane number of diesel oil and the charge characteristics of electromagnetic induction. By measuring the dielectric properties of the sample and comparing with the known parameters in the memory, the result is determined. The instrument is very sensitive and can measure small changes in dielectric parameters. It can detect octane number, cetane number and other petroleum product parameters.
Functions
Test octane number of automotive gasoline, as per ASTM D 2699-86, ASTM D 2700-86.
Test cetane number of automotive gasoline as per ASTM D 4737-03, ASTM D 613, EN ISO 5165.
Determination of diesel freezing point.
Pour point depressant content for diesel fuel.
Kerosene content of diesel fuel.
Gasoline failure period (oxidation resistance), ASTM D 525.
Technical Parameters
Item |
Unit |
Value |
Gasoline octane number range |
ON |
40-125 |
Gasoline octane number measurement accuracy |
ON |
± 0.5 |
Gasoline stability measurement range |
min. |
50-2400 |
Maximum acceptable basic error of gasoline oxidation degradation time measurement |
% |
5 |
Cetane number measurement range |
CN |
20-100 |
Measurement accuracy of diesel cetane number |
CN |
±1.0 |
Maximum acceptable error of diesel fuel freezing point measurement |
C o |
± 2 |
Measurement of kerosene content in diesel fuel |
% |
0-95 |
Measurement mode of pour point depressant content in diesel |
% |
3 |
Maximum acceptable error in measurement of kerosene content in diesel fuel |
% |
0.2-1 |
Maximum acceptable error of pour point depressant content measurement |
% |
0.01 |
Measure time |
s |
1-5 |
Minimum power supply for instrument operation |
V |
5.4 |
Instrument service life |
Year |
6 |
Total size: |
|
|
Electronic unit |
mm |
100х210х40 |
Sensor |
mm |
60х100 |
Instrument weight(including 1 sensor) |
g |
850 |

Function / Feature |
SX-100K |
SX-150 |
SX-300 |
Octane/Cetane Number Measurement |
x |
x |
x |
Diesel mixed type measurement (Winter/Summer/Arctic) |
x |
x |
x |
Condensing point temperature (diesel) |
x |
x |
x |
With built-in memory |
x |
x |
x |
PC / RS-232 interface |
x |
|
|
PC / USB interface |
|
x |
x |
Oil purity measurement |
|
|
x |
Transformer oil fission voltage measurement |
|
|
x |
Transformer oil dielectric dissipation measurement |
|
|
x |
Fuel oil conductivity measurement |
|
|
x |
Anti-knock parameter measurement |
|
|
x |
Diesel pour point depressant content |
|
x |
x |
Kerosene content in diesel |
|
x |
x |
Gasoline oxidation stability |
|
x |
x |
Measurement of failure tangent angle of circuit breaker oil, engine oil |
|
|
x |
Clear level measurement of engine oil and circuit breaker oil |
|
|
x |
Engine oil brand |
|
|
x |
Engine oil base |
|
|
x |
Electric permeability of oil |
|
|
x |
Oil volume resistivity |
|
|
x |
Measurement of mechanical impurities in oil |
|
|
x |
Percentage of water in oil |
|
|
x |
Our Service
Pre -sale Service:
1. Reply promptly in 24 hours with fluent English and professional knowledge
2. Provide best necessary spare parts at low price (some for free)
3. If there is something wrong with the equipment,we will give a response and provide the solutions in 24h
4. Provide long term technical support and innovation upgrade guidance
5. OEM is available for TOP Products
6. Protect sales area, ideas of design and all your private information
After-sale Service:
1.The warranty period is 24 months from commissioning acceptance date on. After the warranty period is over we provide lifelong maintenance and technical service.
2. We guarantee the maintenance time no more than 3 working days and response time within 1 hour.
3. We build instrument service profile for our clients to record the product service and maintenance conditions.
4. After instruments start service, we will pay follow-ups to collect the service conditions.