Fully Automatic Age Transformer Oil Bdv Testing Kits (IIJ-80)

Product Details
Customization: Available
Type: Universal Testing Machine
Maxcapacity: <1000KN
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)
  • Fully Automatic Age Transformer Oil Bdv Testing Kits (IIJ-80)
  • Fully Automatic Age Transformer Oil Bdv Testing Kits (IIJ-80)
  • Fully Automatic Age Transformer Oil Bdv Testing Kits (IIJ-80)
  • Fully Automatic Age Transformer Oil Bdv Testing Kits (IIJ-80)
Find Similar Products

Basic Info.

Model NO.
IIJ-II-80
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
-
Net Weight
36 Kgs
Output&Nbsp;Voltage
60kv/ 80 Kv /100&Nbsp;Kv
Breakdown&Nbsp;Sensitivity
<&Nbsp;0.1&Nbsp;Kv
Dimension
380 mm* 380 mm*380mm
Capacity
2.0&Nbsp;kVA
Transport Package
Wooden Case
Specification
CE, SGS
Trademark
TOP
Origin
Chongqing, China
HS Code
90278099
Production Capacity
1000 Sets/Month

Product Description

Fully automatic Transformer oil BDV test set(IIJ-II)
1 output voltage: 0-100kV
2 LCD display
3 Automatic
4. Thermal printer
5. Meet IEC156

IIJ series fully automatic oil tester is designed as per the requirement of IEC156 Testing Method of Insulation Oil Medium Strength, which via proper programming, has got functions of auto boosting, step down, stirring, display and print out. After breakdown of oil medium, HV break off will operate within 10 seconds to enable an auto isolation of control system partly; This effectively safeguards the personnel security and equipment safety.
The tester is suited for testing of the strength of insulating oil medium, as well as for testing of withstands voltage of transformer oil.

Features:
1) Fully automatic, control by microcomputer, utilization of new I/O terminal.
2) Numbers of times of testing and idling time of stirring are set via digital setting.
3) Test results displayed and printed out automatically.
4) Strong capability of anti-interference.
5) High accuracy of testing and high capacity of anti-jamming.
6) Easy to operate, small size, light weight which operated in the open air very conveniently and convenient
For maintenance
7) Can store 99 groups oil testing data which is convenient to reading and print. The testing data can keep
100 years under the condition of power off.
8) System time can go on running under power off. (the system time just for reference can not be the standard of timing)

Test equipment
1. Transformer oil Breakdown voltage Tester ( BDV test kit) series IIJ-II
2. Acidity tester model ACD-3000I
3. Karl Fischer Water content Tester Model TP-6A / model TP-2100
4. Fully automatic Interfacial Tension Analyzer model IT-800
5. Gas-Chromatography transformer oil gas analyzer model DGA2013-1
6. Multi-functional Vibration tester model TYD-2000
7. Automatic Freezing Point & Pour Point Tester model PT-2000
8. Kinematic Viscosity tester model VST-8 /model VST-2000
9. Flash point tester (open cup) model TPO-3000
10. Flash point tester (close cup) model TPC-3000
11. TAN-DELTA TESTER, 10kV Capacitance and Dissipation Factor Test Set model CDEF
12. Automatic Freezing Point & Pour Point Tester model TP-501Z
13. Determination of foaming characteristic of lubricating oil model SD-12579
14. Earth resistance tester model HYDW-II
15. Coil Resistance Tester (TPZC-40)
16. CT/PT tester model TPVA-404
17. Transformer turn ratio tester model HYG-II
18. Relaying Protection Tester model TPJB-III
19. Digital Grounding Resistance Tester model TP2571-II
20. DC High Voltage Generator model ZGF
21. Underground water/gold detector model TP-UWD
ower supply AC220V± 10%, 50Hz
Output voltage 0-100KV (60KV. 80KV,100KV)
Capacity 1.2KVA (1.6KVA. 2.0KVA)
Speed of pressure rise about 2KV/S
Voltage test precision ± 3%
Breakdown sensitivity < 2KV
Wave difference < 3%
Time of breakdown < 10ms
Working altitude < 1500m (if over 1500m can be designed specially)
Dimension 480mm*460mm*460mm
Working condition
Temperature    30Celsius degree--40Celsius degree
humidity The biggest comparatively humidity85%
Reserve circumstance
 
Temperature
 
-20Celsius degree-60Celsius degree
 