Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
TP-3800F type flame atomic absorption spectrophotometer is the result of the joint research and development by our famous atomic absorption experts and senior engineers, not only the instrument level is of a higher grade, but also the instrument sensitivity has reached a new level. The product includes flame, hydride generation system, optional accessories up to several kinds, flexible configuration can meet the needs of different customers. The instrument is mainly used for the analysis of metallic elements, semi-metallic elements and alkaline earth metals, some non-metallic elements and organic substances can also be done by molecular absorption. It is widely used in various fields such as geology, metallurgy, mining, petroleum, chemical industry, machinery, agriculture, food, medicine, health, epidemic prevention, environmental protection, pharmaceuticals, etc. It is an essential high precision analytical instrument for various research institutes, universities and related enterprises.
1,High precision fully automated optical system
Dispersion of 1800 bars/mm inscribed large area grating, new self-collimating monochromator, all lenses are quartz coated. Wide detection range and optical stability to ensure the accuracy of the analysis. Fully automatic 8-lamp holder configured with 8 individual lamp power supplies and 1 background-corrected hollow cathode lamp.
2,Nebulisers
Our nebulisers are available in three sizes: ordinary glass high-efficiency nebulisers, adjustable nebulisers and hydrofluoric acid-resistant nebulisers. Whether organic or inorganic solutions can be obtained the highest sensitivity and stability, to meet the needs of different customers measurement samples.
3. All -titanium burning head
The whole titanium burns, corrosion resistance, high salt resistance, stable combustion, high atomic efficiency, greatly increase the accuracy of flame analysis.
4. Fully automated analysis
Eight -lamp rack automatic switching devices are used to meet the needs of various element testing. The wavelength is automatically scan, automatic peak search, automatic switching spectral bandwidth, automatic adjustment of negative high voltage, light current, etc., systematic settings, flexible operation. The semi -transparent and semi -anti -device, the background of the lamp buckle, the sample beam and the background beam energy automatically balanced. The highly automated function meets the needs of users to the greatest extent.
5. Humanized software design
High -intelligent software, powerful, friendly Chinese operation interface. After the self -inspection is turned on, the software can automatically detect communication, wavelengths, slits and lights. The quality control diagram of all different statistical methods can be preserved, and at the same time, it can automatically dilute and automatically configure the curve to control the flame combustion to help ratio.
TP-3800F | ||
Host |
light source | Element hollow cathode light |
Lamp seat | Eight lights automatically switch | |
Lamp current | Double circuit Stability flow power supply | |
Optical system | 1800/mm imported grating | |
Device | C-T type | |
Wavelength | 190~900nm,Wave length automatically scan, automatic peak search | |
Wavelength accuracy | ±0.1nm | |
Wavelength repetitiveness | 0.1nm | |
Spectral bandwidth | 0.2,0.4,1.0,2.0.Four gear automatic switching | |
Baseline drift | 0.003A/30min | |
Absorbent | 0.001~2.000Abs,0.0001~2.0000Abs | |
Detector | High -sensitivity imported photoelectric multiplier pipe | |
Background correction | Light background correction, self -priming background correction | |
Flame system |
Burning head | Titanium alloy burning head, 0.6mm*100mm titanium steel |
Atomizer | Metal sleeve glass high -efficiency atomizer | |
lighter | Electronic torch ignition | |
Gas control | Full automatic gas control system | |
Characteristic concentration | 0.02μg/mL/1%(Cu) | |
The detection limit | 0.002μg/mL(Cu) | |
Repetitiveness | RSD≤1.0% | |
safety | Acetylene leaks alarm, flames monitoring, and automatic protection of flameouts, and automatic power off protection protection when other abnormalities occur. | |
data processing | Measurement method | Atomic absorption method, hydride method, launching method |
Concentration calculation method | Standard curve method, standard addition method, and light absorption method | |
Number of repeat test times | In any number of times, the standard deviation, relative standard deviation, and accuracy can be calculated |