Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
I. Technical Requirements:
1 Adopt the latest multi-core embedded technology for fully automatic control and data processing of the instrument to ensure reliability.
2 High-performance LCD display, display parameters and measurement data.
3 Automatic adjustment of negative high voltage and lamp current.
4 Automatic conversion of spectral bandwidth, 0.1, 0.2, 0.4, 1.0, 2.0nm (five gears are optional).
5 Automatic control of wavelength scanning, automatic peak-seeking, international level of full-band rapid scanning and positioning, completed within 30 seconds.
6 Automatic adjustment of negative high pressure, lamp current; automatic setting of gas flow, automatic selection of the best combustion ratio for elemental analysis. Advanced and reliable safety protection system to protect the safety of operators in all aspects.
7 Automatic zero adjustment, can deduct the impact of zero point drift on data; automatic energy adjustment.
8 Automatic ignition, automatic flow setting, automatic protection for flame out, all-round gas leakage protection warning device, so that you can work with confidence and ease.
9 The best flame height and atomizer position can be selected to choose the best analysis conditions.
10 Excellent quality optical system, optical system suspension design, vibration, ambient temperature changes do not affect the performance of the instrument. Strong light energy, good stability.
11 Fast six-lamp automatic turret and wavelength scanning technology, available high-performance cathode lamp.
II Technical parameters:
1 Optical system
1.1 Wavelength range: 190nm-900nm
1.2 Monochromator: C-T type monochromator with elimination of parallax, 1800 bars/mm
1.3, Spectral bandwidth: 0.1, 0.2, 0.4, 1.0, 2.0nm (five gears optional)
★1.4 Wavelength accuracy: ±0.1nm
★1.5 Wavelength repeatability:0.1nm
1.6 Baseline drift:0.004A/30min
2 Flame atomization system
2.1 Characteristic concentration:0.02.0ug/ml/1%
★2.2 Detection limit:( Cu ) 0.002μg/ml
2.3 Burner:100mm metal titanium burner, air-cooled premixed type
★2.4 Repeatability (RSD): ≤1%
2.5 Nebulizer: high-efficiency glass, all-plastic, stainless steel nebulizer
2.6 Atomization chamber: corrosion-resistant material atomization chamber
2.7 Position adjustment: the best height of the flame burner and the front and rear position automatically set adjustable, one minute to complete the flame / hydride change
2.8 Safety protection: with a variety of automatic safety protection functions, acetylene leakage alarm, shutdown system