• ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150
  • ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150
  • ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150
  • ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150
  • ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150

ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150

Test Range: 0.001g ~120g
Gasoline Octane Number Range: 40–125 &Plusmn
Gasoline Octane Number Measurement Accur: ± 0.5
Gasoline Stability Measurement Range: 50-2400min
Cetane Number Measurement Range: 20–100
Measurement Accuracy of Diesel Cetane Nu: ±1.0
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Chongqing, China
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)

Basic Info.

Model NO.
SX-150
Measurement of Kerosene Content in Diese
0-95%
Measure Time
1–5s
Transport Package
Standard Export Wooden Case
Specification
Customizable
Trademark
TOP Tester
Origin
Chongqing, China
HS Code
9030899090
Production Capacity
100 Sets Per Month

Product Description

ASTM D 4737- 03 Diesel Cetane Measurement Model SX-150

ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150
Whether in the field or in the laboratory,this analyzers are leaders in portable rapid analysis instruments. We designs and produces analytical instruments for gasoline, diesel, motor oil and transformer oil.

Portable octane and cetane analyzers are often used for on-site analysis of octane number of power gasoline, corresponding to the motor method and research method (RON and MON), and also suitable for cetane number analysis of diesel. In addition, the temperature of the analyzed liquid and the freezing point of diesel can also be measured, and the measurement results are displayed on the LCD liquid crystal display.

Octane and cetane analyzer is widely used all over the world. Its measurement method conforms to international standards: octane measurement conforms to: ASTM D 2699-86, ASTM D 2700-86; diesel cetane measurement conforms to: ASTM D 4737- 03, ASTM D 613, EN ISO 5165.



ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150
1.TP-225 consists of standard color disc, observation optical lens, light source, colorimetric tube.
2.Take the inside-frosted bulb of 220V / 100W and color temperature 2750 ± 50K as standard light source. After Source light color filter through the milky glass and sunlight filter glass, the spectral characteristics of the resulting standard light similar to North Light.

3.The light of petroleum products Chroma tester through the filter, then form two parallel beams, their size and shape are exactly the same, uniformly irradiated on the sample of color glass in standard color wheel and sample colorimetric tube, and through the prism and lens reflex, then enter into the eyepiece.

4.There are 26 Φ14 light holes, of which 25 were 1-25 sequence containing color number standard color glass sheet, the twenty-sixth is blank, the color wheel on the right side hole, so that the operator selects the correct standard corresponding color when toggle the standard color wheel, and compares the standard color in standard color wheel and color of samples in color tube.

 ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150                
# Parameter description Measurement units Value
1 Measured petrols octane numbers range ON 40-135
2 Acceptable limit of octane number measurement basic error, max ON ±0.5
3 Limit of acceptable difference between parallel octane number measurements, max ON ±0.2
4 The determination range of antiknock additives content in petrols % 0.5-15
5 Acceptable basic error limit of antiknock additives content determination in petrols % 0.1
6 Petrol oxidation breakdown time measurement range Min 50-2400
7 Acceptable basic error limit of petrol oxidation breakdown time % 5
8 Petrol quality determination mode basing on volume resistivity
Ohm
10 6-10 14
9 Acceptable basic error limit of volume resistivity measurements
%
3
10 Cetane numbers measurement range CN 20-100
11 Acceptable basic error limit of cetane numbers, max CN ±1.0
12 Acceptable difference limit between cetane numbers parallel measurements, max
CN

± 0.5
13 Acceptable error limit when determining diesel-fuel pour point ºC 2
14 Kerosine content determination range in summer diesel fuels % 0-50
15 Acceptable basic error limit when determining kerosene content in diesel fuels
%

3
16 Mode for pour point depressants content determination for diesel fuel % 0.2-1
17 Acceptable basic error limit when determining of pour point depressants content % 0.01
18 Motor oils clarity level measurement range % 50-100
19 Acceptable error limit of motor oils clarity level measurement % 0.1
20 Acceptable difference limit between motor oils clarity parallel measurements % 0.01
21 POL dielectric permeability measurement range units 1-5
22 Acceptable error limit of dielectric permeability measurement, max unit 0.001
23 Acceptable difference limit between POL dielectric permeability parallel measurements, max unit 0.001
24 Oils base number determination range unit 3-24
25 Acceptable basic error limit when determining oils basic number BN unit 1
26 Motor oils manufacturer and brand determination Manufacturer -
27 Circuit-breaker oils (dielectrics) breakdown voltage measurement range kV 5-100
28 Acceptable error limit of circuit-breaker oils breakdown voltage measurement, max kV 1
29 Acceptable difference limit between circuit-breaker oils breakdown time parallel measurements, max kV 0.2
30 Measurement range of circuit-breaker oils loss angle tangent % 0.01-40
31 Acceptable error limit of circuit-breaker oils loss angle tangent, max % 0.01
32 Acceptable difference limit between circuit-breaker oils loss angle tangent parallel measurements, max units 0.001
33 Determination range for mechanical impurities content in oil products % 97-100
34 Acceptable basic error limit when determining mechanical impurities content in oil products % 0.01
35 Water-in-oil content determination range for oil products % 0-30
36 Acceptable basic error limit when determining water-in-oil content of oil products % 1
37 Measurement time sec 1-5
38 Insufficient power supply indication operation threshold V 5.4
39 Instrument useful life   6
40 Overall dimensions of:    
  electronic module mm 100х210х40
  sensor #1 and #2 mm 60х100
  Instrument mass with one sensor/two sensors g 850 / 680
                                                                                             
ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150
ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150
ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150
 
MOQ 1 Set
Trade Terms EXW, FOB, CIF, CFR
Payment Terms T/T, L/C
Port of Loading Any Port of China
Packing Method Internaional Standard Wooden Case
Transportation Method By Sea, By Land, By Air, By Express
Supply Capability 100 Sets/Month

ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150

 

ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150

ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150ASTM D 4737- 03 Diesel Cetane Measurement Model Sx-150

☎ Exhibition