Outdoor Vacuum Type Insulating Oil Purification Machine (ZYD-W-150)

Certification: ISO9001, CE
Application: Transformer Oil, Transformer/Switch/Insulation Oil
Voltage: 380V
Folw Rate: 150 L/min
Structure: Mobile
Mechanical Principle: Vacuum
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Chongqing, China
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)

Basic Info.

Model NO.
ZYD-W-150
Type
Suction Filter
Color
Yellow
Size
1450*950*1650mm
Net Weight
1500 Kg
Transport Package
Wooden Case
Specification
CE, SGS
Trademark
TOP
Origin
Chongqing, China
HS Code
84212990
Production Capacity
1000 Sets/Month

Product Description

Outdoor Vacuum Type Insulating Oil Purification Machine (ZYD-W-150)

1. Improve breakdown voltage up to 75KV
2. High dehydration and degassing

Application:
Series ZYD Double-stage vacuum Transformer oil purifier machine is special for treating the used and old transformer oil, mutual oil, switch oil. Comparing with the single stage type, this machine adopts the double stages vacuum system, which can improve the machine working vacuum value highly, so it can remove the water, gas and impurities in insulation oil high-efficiently, increasing the pressure force and quality of oil, make sure the electric device running safely. Also it can inject the insulation oil into the transformers on line, regeneration the seriously deteriorated oil by removing the polarity materials. The machine is specially applied to vacuum filling oil and drying for power transmission equipments that are over 110KV.

The oil technical data after treatment:
1. Gas content less than 0.1%
2. Impurity size less than 1μ M without free carbon
3. Oil dielectric strength (breakdown voltage) more than 75KV
4. Acidity value less than 0.01 mgKOH/g
5. Dielectric loss factors at 90° C less than 0.001

Feature:
1. PH of treat oil ≥ 5.5 2. Acid value ≤ 0.03mgkoH/g
3. Flash point ≥ 145° C 4. Anti-pressure≥ 75KV
5. Dielectric loss: Dielectric loss: Tg δ (90° C)% ≤ 0.001
6. High vacuum: High point-vacuum ≤ 5Pa; Working-vacuum ≤ 35Pa
7. High absorption speed: Absorption speed power ≥ 333L/Sr.
8. Duplex 3D stereo-evaporation, eliminating the liquid water quickly
9. UK G technology, by which the trace water that is show chain, such as dissolved water, can be removed effectively
10. Instinctively removing impurities system filtering through the double FH trapezoidal network and absorbing by high polymer without mechanical power
11. Argon fiber infrared heating system that can make the oil contain zero sum of ethyne after the treatment.

If you have any interestedour machines, we will send the suitable oil purifier document for your reference soon.


Optional:
A. Without enclosure, open and stationary type
B. With enclosure, cubicle and stationary type
C. With skid base type
D. Mounted in casters
E. Mounted on single-axle trailers (pneumatic tyre, speed selectable)
F. Mounted on double-axle trailers (pneumatic tyre, speed selectable)
D. PLC type

You may also be interested in:
A. Transformer oil tester, testing the insulating oil's delectric strength
B. Vacuum pumping set, pumping the transformer
C. Moisture Meter, measuring the water content in the transformer oil
D. Flow Meter, measuring the flow oil quantity through the machine

Test equipment
1. Transformer oil Breakdown voltage Tester ( BDV test kit) series IIJ-II
2. Acidity tester model ACD-3000I
3. Karl Fischer Water content Tester Model TP-6A / model TP-2100
4. Fully automatic Interfacial Tension Analyzer model IT-800
5. Gas-Chromatography transformer oil gas analyzer model DGA2013-1
6. Kinematic Viscosity tester model VST-8 /model VST-2000
7. Flash point tester (open cup) model TPO-3000
8. Flash point tester (close cup) model TPC-3000
9. TAN-DELTA TESTER, 10kV Capacitance and Dissipation Factor Test Set model CDEF
10. CT/PT tester model TPVA-404
11. Transformer turn ratio tester model HYG-II
12. Relaying Protection Tester model TPJB-III
Parameters Unit ZYD-30 ZYD-50 ZYD-100 ZYD-150 ZYD-200 ZYD-250 ZYD-300
Flow Rate L/H 1800 3000 6000 9000 12000 15000 18000
Working vacuum MPa -0.08 ~ -0.099
Working Pressure MPa ≤0.3
Temperature Range C 20 ~ 80
Power   Three Phase 50Hz,380V (or as needed)
Working Noise dB(A) 70 70 70 75 75 75 75
Heating Power kW 28 30 45 60 75 90 120
Total Power kW 35.5 37.5 52.5 71.4 86.5 102.5 135
Inlet/Outlet   mm φ25 φ32 φ42 φ50 φ50 φ60 φ60
Weight Kg 600 800 1050 1400 1800 2000 2200
Overall L mm 1050 1100 1200 1450 1600 1800 1900
W mm 750 800 950 950 1100 1200 1200
H mm 1350 1400 1500 1650 1800 1900 1900

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now