|
FOCUS ON OIL FILTRATION SYSTEM OVER 20 YEARS
Recycling your used oil reduces pollution and protects our environment.
Conserving a valuable resource and getting paid for it.
Chongqing TOP Oil Purifier Co.,Ltd. |
Product Description
Product Show:
Online Particle and PPM Meter PTT-M
Application:
PTT-L3 oil particle counter is based on GB/T18854-2002-(ISO11171-1999) and other standards. It is developed using the counting principle of the photoresist (shading) method, which fully conforms to the corresponding national military standards, national standards and international standards. It can provide fast, accurate, reliable and repeatable test results and complete pollution monitoring and analysis reports. It can be widely used in aviation, aerospace, electric power, petroleum, chemical industry, transportation, port, metallurgy, machinery, automobile manufacturing and other fields.
Features:
1.Adopt the counting principle of the photoresist (shading) method formulated by the International Hydraulic Standards Committee.
2.High-precision laser sensor, wide test range, stable performance, low noise and high resolution.
3.High-pressure syringe pump sampling method is adopted, the sampling volume can be set by itself, the sampling speed is stable, and the sampling accuracy is high.
4.The positive and negative pressure combined sample injection system can realize sample degassing, which is suitable for testing samples of different viscosities.
5.Built-in pressure sensor, which can directly set the pressure value, and automatically judge the air pressure in the cabin to ensure safety.
6.Built-in air purification system to ensure that the test is not polluted.
7.Built-in SAE4059E, SAE4059F, SAE4059F-CPC, NAS1638, ISO4406, GB/T14039, GJB-420A, GJB-420B, ГOCT17216-71, DL/T1096, SAE749D, JBT9737.1, QC/T29104-201, DL-T432- More than a dozen common standards such as 2018, HH005-2018, etc., support arbitrary addition of custom standard tests, and there is no upper limit on the number of custom standards added, and the required standards can be set according to customer needs.
8.Built-in data analysis system, one test can give all standard test data and pollution level10.Built-in viscosity, moisture and temperature sensor modules provide viscosity, moisture content saturation, ppm value and temperature reference value while accurately testing particle distribution (optional).
9.Built-in multiple calibration curves, compatible with all commonly used standards at home and abroad, for single-channel or multi-channel automatic calibration.
10.The particle size can be set arbitrarily, with nearly 10,000 particle sizes built-in, which is convenient for particle size analysis.
11.Various sampling containers such as standard sampling bottles or sampling cups can be used to meet the testing requirements of different industries.
12.Optional viscosity, dielectric constant, moisture and temperature sensor modules to achieve multi-parameter testing.
13.Windows operation interface, built-in database, unlimited data storage, can use test standard, sample name, sample batch number, tester, test time and other methods to search and query.
14.Multi-level account authority management, account authority can be set separately, and digital signature is supported.
15.The test results can be printed on a micro or desktop printer, and can be exported to pdf, excel and other formats, and can be transmitted through USB, wifi, etc.
Technical Indicators:
1.Optical system: photoresist method (shading type)
2.Light source: semiconductor laser
3.Measuring range: 0.8μm~600μm (depending on different sensors)
4.Measuring channels: 64 channels (the number of channels can be edited at the same time), the particle size is arbitrarily set by the user
5.Sensitivity: 0.8μm (ISO4402) or 3μm (c) (GB/T18854, ISO11171)
6. Resolution: <10% (GB/T18854, ISO11171)
7.Repeatability: RSD<2%
8.Test sample viscosity: ≤650cSt (when the viscosity is too large, it can be tested with heating or dilution method)
9.Sampling volume: 0.2~6000ml, interval 0.1ml
10.Sampling speed: 5 ~ 80mL/min
11.Sampling volume accuracy: better than ±0.5%
12.Air pressure chamber: positive and negative pressure air pressure chamber device, realize sample degassing and high viscosity sample detection
13.Maximum vacuum of air pressure chamber: -0.08MPa
14.Maximum positive pressure of air chamber: 0.8 MPa
15.Overlap error limit: 12000~40000 capsules/mL
16.Temperature acquisition (optional): -40~100ºC Accuracy: ±0.5ºC
17.Moisture (optional): Water activity collection: 1~100%RH; Accuracy: ±1%RH
18.Absolute water content: 1~300ppm; Accuracy: ±10ppm
19.Dielectric constant (optional): 1~6
20.Viscosity (optional): 0.5~50cP Accuracy: ±2% (>10cP), ±0.2cP (<10cP)
21.Power supply: 110~245V AC, 50Hz, 70W
22.Dimensions: 340mm*310mm730*mm
23.Instrument net weight: 25kg
Payment Terms:
MOQ |
1 Set |
Trade Terms |
EXW, FOB, CIF, CFR |
Payment Terms |
T/T, L/C |
Port of Loading |
Any Port of China |
Packing Method |
Internaional Standard Wooden Case |
Transportation Method |
By Sea, By Land, By Air, By Express |
Supply Capability |
100 Sets/Month |
After-sale Service:
* The warranty period is 24 months from commissioning acceptance date on. After the warranty period is over we provide lifelong maintenance and technical service.
* We guarantee the maintenance time no more than 3 working days and response time within 1 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.
Company Profile
Our Company:
Chongqing TOP Oil Purifier Co., Ltd
Located at Chongqing city--a southwest electromechanical manufacturing center as well as national municipality, Chongqing TOP is a professional leading manufacturer and supplier of oil purifiers and various related testers. Our company consists of departments respectively for technological development, machinery manufacture, instrument manufacture and quality control etc.
Exhibition:
Our Factory:
WELCOME YOUR INQUIRY