Customization: | Available |
---|---|
Certification: | CE |
Structure: | Mobile |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Applicable boiling range: petroleum products or distillates of 55~550ºC boiling range distribution
such as fuel, kerosene, diesel, lubricants, wax oil etc. On this chromatographic condition tested sample components can all show the peaks. It adopts area normalization method to fix quantity. It complies to SH/T 0558-2002 and ASTM D2887standard.
2. Applicable boiling range: crude oil of initial boiling point~538ºC boiling range distribution. Get distribution proportion of fuel, diesel, kerosene, heavy oil. Since the heavy components above 538ºC can not show peak, it adopts incremental internal standard method and complies to ASTM D5307 standard.
3. Applicable boiling range: petroleum products or distillates of 55~680ºC boiling range distribution.
On this chromatographic condition tested sample components can all show the peaks. It adopts area normalization method to fix quantity.
Features:1. Adopts American Agilent 5890 gas chromatographic core tech; green backlight LCD screen; easy operation
2. Temperature control upper limit max use temperature of 450ºCfor every instrument heating area.
3. Dual channel single column compensation; base line drift when program heat to operate FID test; ensure base line straight and chromatography peak shape perfect.
4. Adopts imported heat-resistant large aperture metal capillary column to separate; mas analysis
use temperature of 450ºC.
5. Can display and print C5-C44 n-alkanes calibration sample boiling point-time calibration curve.
6. Can provide oil sample boiling point-yield boiling range curve.
7. Can provide detailed boiling range report regarding 1% yield interval; also can provide it regarding 5ºC, 10ºC, 20ºC, 30ºC, 50ºC, 100ºC boiling range.
8. Can be equipped with AS-2902 highly efficient auto liquid sample injector; auto injection
analysis with unattended operation achieved; analysis efficiency improved and labor intensity reduced.
Temperature control index
Oven/ Sample injector/ detector: above room temperature 5ºC~450ºC; precision ±0.1ºC
Column oven parameters
Temperature control range: above room temperature 5ºC~450ºC; precision ±0.1ºC
Program heating stages: 3 stages
Program heating speed: 0.1ºC~50ºC, increment 0.1ºC
Program heating keeping time: 0~655 min (increment 1 min)
Big oven volume; back pullout design; program quick cooking after heating. Cooling speed: only 7min from 350ºC down to 60ºC.
Injection method
Capillary split/unsplit stream injection: flash distillation injection
Packed column head injection: flash distillation injection
Can be equipped with unattended operation auto injector.
Hydrogen flame ionization detector (FID)
Easy disassembly and installation; convenient for cleaning and displacing nozzle; easy operation; can input signal to logarithmic amplification to reduce interference; high sensitivity, good linearity and wide range.
Limit of detection (LOD): Mt ≤ 5×10-12g/s (n-Hexadecath)
Baseline noise: ≤ 6×10-12A/H
Linearity range: ≥ 105
Stability time: < 0.5h
Chromatographic working station
24 bits high precision digital-to-analogue conversion (DAC)
Dual channel synchronous or asynchronous work
USB port; can be connected to external power supply; with serial port
Input voltage range: -1V~1V
Integral sensitivity: 0.05uV•s
Min solution: 1uV
Dynamic range (DR): 107
Sample frequency: Max 60 times/sec; adjustable program variables
Diesel simulated distillation spectrogram
N-alkanes analysis spectrogram
C5-C44 n-alkanes calibration sample boiling point-time calibration curve
oil purifier, oil filtration, oil purification, oil filter, oil treatment, oil saving, oil recycling, oil processing, oil filtering, energy saving, oil regeneration, oil processor, oil filter, oil process, oil purify, oil regenerating, oil restoration, waste oil disposal, oil reclaimed, oil reclaiming, waste oil management, oil regenerate, oil reconditioned, oil reconstituted, oil restituting, oil recovering, oil recondition, oil filters, oil refinery, oil refiner, oil cleaning, oil recycle, oil reclaiming, oil separating, oil recovery, oil recycle, oil reclamation, oil refinery, oil separator, oil separation, oil purifiers, oil recondition, oil dehydrator, oil water separator, oil dehydration, machine recycling used oils, waste oil filter, oil degasifier, waste engine purifier, oil refinery plant, mini petrol refinery, oil recycling machine, quenching oil filter; Oil tester, analysis instrument, testing equipment, testing machine, testing kit, testing device, oil testing kit, testing unit, test equipment, test machine, test device, lab analyzer, lab instruments, lab test equipment, lab test kits, lab testing, laboratory equipment, measurement meter, measurement test equipment, measuring & gauging tools, measuring device, measuring equipment, measuring instruments, measuring tester, moisture content sensor, new measuring instruments, oil analyser, oil analysis, oil analysis equipment, oil analyzer, oil lab equipment, oil test kit, oil measuring instrument, tools and equipment, testing laboratory, testing instrument, tester unit, tester set, oil testing machine, tester device, test kit, test equipment, test and measurement, oil testing unit, oil testing machine, oil testing device, oil tester machine, oil test equipment, oil quality analyzer, oil moisture sensor, oil moisture meter, analysis equipment, oil test set etc.