Bet Surface Area and Pore Size Analyzer for Determination of Pore Volume, Size and Distribution

Max Diameter of Workpiece: <500mm
Mass Scope of Workpiece: <900kg
Type: Material Testing Machine
Maxcapacity: <1000KN
Accuracy Grade: 0.5
Load Way: Electronic Load
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Chongqing, China
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)

Basic Info.

Model NO.
TP-112GB
Loading Method
Dynamic Load
Display
Needle
Control
Computer Control
Weight
100-500Kg
Power Source
AC220V
Oil Cylinder Position
Top
Transport Package
Wooden Case
Trademark
TOP TESTER
Origin
China
HS Code
9027

Product Description

Surface Area and Pore Size Analyzer TP-112GB


 Specifications -
Power
Voltage:                   100V~230V ± 10V
Frequency:              50/60Hz
Maximum power:  300W
Connection:            grounding, single-phase power socket

Physical properties
Length:                    74cm (29.1 inches)
Width:                     50cm (19.7 inches)  
Height:                    94cm (37.0 inches)
Weight:                   60kg (132.3 lbs)
Accessories Weight:                 31kg (68.3 lbs )
Installation requirements:       L 100 * W60cm (not including space computers taking up)

Work environment
Temperature:                            15ºC -40ºC
Maximum relative humidity:  30%--60%


- Functions -
 Surface area measurement: 
BET surface area (single -point and multi-point)
STSA
Langmuir surface area
T-plot method the total inner surface area of micro pore
BJH adsorption cumulative surface area of the total pore
BJH desorption cumulative surface area of the total pore

 Determination of pore volume:
Single point total pore volume
BJH adsorption cumulative total pore volume
BJH desorption cumulative total pore volume
plot method the total pore volume of micro porous

 Determination of average pore size:
Adsorption average pore diameter
BJH adsorption average pore diameter
BJH desorption average pore diameter
The most frequency pore

 Pore size distribution:
BJH adsorption and desorption differential pore size distribution (dV/dD-D) and (dV/dlogD-D)
BJH adsorption and desorption /integral distribution (or cumulative distribution)
MP method micropore distribution


- Technical Parameters -

▪ Adsorbed Gas :     Non corrosive gases, such as N2, Ar, Kr, H2, O2, CO2, CO, NH3, CH4, etc.
▪ Pressure Sensor at Analysis Station :   
1000 torr, 1;   Accuracy: ±0.15% (F.S.)
 Pressure Sensor at P0 Station :    1000 torr; Accuracy: ±0.15% (F.S.)
▪ Degas System :     Samples at 2 stations can be pretreated simultaneously under vacuum
                     with heating
▪ Degas Temperature :   Ambient to 400 ºC. Free to set up target temperature
▪ Vacuum Pump :      Two-stage rotary vane mechanical vacuum pump,
 the ultimate vacuum is 6.7*10-2 Pa
▪ Analysis Port :      Samples on the 2 analysis bits can be tested alternately
▪ Test Principle :     Gas adsorption by static-volumetric analysis
▪ Measurement Range of Specific Surface Area : 
0.0005 m2/g to the infinity;
 Standard sample repetition is less than ± 1.0%
▪ Test Range of Pore Diameter :    
0.35 nm-500 nm;
 pore repeated deviation is less than 0.2 nm in the accurate analysis of
 porous materials with pore greater than 2 nm
▪ Minimum Pore Volume :  0.0001 cm3/g
▪ Range of Relative Pressure P/P0 :  10-4-0.998


- Product Features -
- Single station analysis; two ports can be carried out degassing simultaneously. The highest temperature of degassing is 400ºC;
- Multi-point BET surface area test can be done automatically within 40-60 minutes; (not including degassing time);
- With liquid nitrogen surface control systems and integrated software compensation technology, it is ensured that the non-uniform temperature field of the test sample chamber is constant relatively;
- The introduction of advanced technology thermostat folder, with a large capacity vacuum liquid nitrogen dewar and anti-volatile elements;
- Adjustable multi-channel parallel-controlled vacuum system, built-in anti-splash units, and "Ladder" splash procedures to effectively prevent ultrafine powder from flying away, completely avoid the contamination of the instrument;
- A control valve position indicator is on the instrument control panel, and the experimenter can be more visible and intuitive to control valves, user-friendly design;
- Equilibrium pressure intelligent control technology, the sample absorption / desorption equilibrium pressure determine automatically and data acquisition, adsorption-desorption isotherms curve test points can be controlled automatically;


- Intelligent TP-specific software -
- On Windows platforms, providing control program of automated testing process, continuous rapid data acquisition, orderly and efficient data processing, editing, computing, mapping, storage, and gives the final results and full test reports;
- Ethernet data acquisition and processing software, operation is guided, and a set of software can simultaneously control multiple instruments, remote control;
- Various theoretical models and data analysis methods;
- Surface area:(single, multi-point), the three-parameter BET, Langmuir ;     
- Mesopore analysis: BJH method, DR, t-Plot,MP, etc.

Bet Surface Area and Pore Size Analyzer for Determination of Pore Volume, Size and DistributionBet Surface Area and Pore Size Analyzer for Determination of Pore Volume, Size and Distribution

Bet Surface Area and Pore Size Analyzer for Determination of Pore Volume, Size and DistributionBet Surface Area and Pore Size Analyzer for Determination of Pore Volume, Size and Distribution
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now