• Mobile Two-Stage Insulating Oil Filtration Plant (ZYD-M-50)
  • Mobile Two-Stage Insulating Oil Filtration Plant (ZYD-M-50)
  • Mobile Two-Stage Insulating Oil Filtration Plant (ZYD-M-50)
  • Mobile Two-Stage Insulating Oil Filtration Plant (ZYD-M-50)
  • Mobile Two-Stage Insulating Oil Filtration Plant (ZYD-M-50)
  • Mobile Two-Stage Insulating Oil Filtration Plant (ZYD-M-50)

Mobile Two-Stage Insulating Oil Filtration Plant (ZYD-M-50)

Certification: ISO9001, CE
Application: Transformer Oil
Voltage: 380V
Folw Rate: 50 L/min
Structure: Mobile
Mechanical Principle: Vacuum
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Chongqing, China
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)

Basic Info.

Model NO.
ZYD-M-50
Type
Press Filter
Power Supply
380V 50Hz
Color
as Needed
Transport Package
Wooden Case
Specification
CE; ISO
Trademark
TOP
Origin
China
HS Code
84212990
Production Capacity
1000 Sets/Month

Product Description

Mobile Two-Stage Insulating Oil Filtration Plant (ZYD-M-50)

1. Dehydration, degasing, remove out particles, residuals and other impurities in oil
2. Improve insulator oil's dielectrical stregth; (more than 75KV)
3. Can also serve as transformer oil filler and dryer for transformer. Mobile type vacuum Transformer oil recycling machine mounted on trailer remove the water, gas and impurities in insulating oil

Series ZYD-M Mobile type Double-stage vacuum Transformer oil purifier can remove the water, gas and impurities in insulation oil high-efficiently, increasing the pressure force and quality of oil, make the oil limiting voltage-withstand value much higher and make sure the electric device running safely. The machine is mainly used for electric power department and industries to deal with various oils such as transformer oil, mutual oil, switch oil, dielectric oil, insulating oil and so on. It also can be used for filtration of more than 110KV substation live line work onsite. Meanwhile, as the bridge-type vacuum linking system, Series ZYD-M oil purifier can be used as independent vacuum source with functions of vacuum drying and vacuum oiling.

Comparing with the single stage type, this machine adopts the double stages vacuum system, which can improve the machine working vacuum value highly, so it can remove the water, gas and impurities in insulating oil high-efficiently, increasing and maintain the oil's dielectric strength more higher.

According to fieldwork requirement, this machine equips car wheels, which can be easily moved to any work point by traction. It is especially suitable for purifying oil which locates in fields.

(oil filtration, oil purification, oil treatment, oil purifier, oil filter, oil recycling, oil processing, oil filtering, oil purifying, oil regeneration, oil filteration, oil purify, energy saving, oil processor, oil filter, oil process, oil regenerating, oil restoration, waste oil disposal, oil reclaimed, oil reclaiming, waste oil management, oil regenerate, oil reconditioned, oil reconstituted, oil restituting, oil recovering, oil recondition, oil filters, oil refinery, oil refiner, oil cleaning, oil recycle, oil reclaiming, oil separator, oil recovery, oil recycle, oil reclamation, oil refinery, oil separator, oil separation, oil purifiers, oil recondition)

Our oil filtration machine:
Series ZY Single-Stage Vacuum Transformer Oil Purifier
Series ZYD Double High Vacuum Transformer Oil Purifier
Series ZYB Multiply-Function insulating oil treatment machine
Series TY Turbine Oil Purification Apparatus
Series TYA Lubricating oil/ hydraulic oil purification unit
Series TYB Portable light Fuel oil purification machine
Series TYD Vacuum dehydrator
Series TYF Phosphate ester fire-resistance oil purifier
Series PL Plate pressure oil purifier
Series TYD Vacuum dehydrator
Series EFD Explosion protection filtration machine
Series BAM Press filtration system
Series ZKCC Vacuum pumping device
Series COP Cooking oil purification machine
Series CYS Centrifugal oil purification machine
Series JL Portable oil filtering and oiling machine
Series EOR series waste engine oil recycling system


Test equipment
1. Transformer oil Breakdown voltage Tester ( BDV test kit) series IIJ-II
2. Acidity tester model ACD-3000I
3. Karl Fischer Water content Tester Model TP-6A / model TP-2100
4. Fully automatic Interfacial Tension Analyzer model IT-800
5. Gas-Chromatography transformer oil gas analyzer model DGA2013-1
6. Kinematic Viscosity tester model VST-8 /model VST-2000
7. Flash point tester (open cup) model TPO-3000
8. Flash point tester (close cup) model TPC-3000
9. TAN-DELTA TESTER, 10kV Capacitance and Dissipation Factor Test Set model CDEF
10. CT/PT tester model TPVA-404
11. Transformer turn ratio tester model HYG-II
12. Relaying Protection Tester model TPJB-III
Technical data ZYD-M -30 ZYD-M -50 ZYD-M  -75 ZYD-M -100 ZYD-M  -150 ZYD-M  -200 ZYD-M  -300 ZYD-M  -500 ZYD-M  -1000
Rated Flow rate (L/h) 1800 3000 4500 6000 9000 12000 18000 30000 60000
Heating Power (kw) 30 42 54 60 84 108 156 225 450
Total Power (kw) 33 46 60 67 94 119 173 257 511
Inlet(outlet) Dia.(mm) 25 32 40 40 50 50 65 80 100
Dimensions(cm)  L 1380 1500 1750 1900 2100 2300 2600 3200 3600
W 1100 1200 1250 1280 1300 1300 1380 1500 1600
H 1600 1650 1650 1700 1800 1850 1950 2100 2300
Net Weight (kg) 600 800 900 1050 1500 1800 2200 3960 4980
Notice: Due to different type and components of product, the technical data may vary slightly.
 
Guarantee Performance Index
Insulation  Oil Before Treatment After One Time Treatment After the Treatment of few Times
Water Content in the Oil  ≤ 50PPm ≤ 15PPm ≤ 3~5PPm
Gas Content in the Oil  ≤ 12% ≤ 0.5% ≤ 0.1%
Flash Point  ≤ 135  C ≥135  C ≥135  C
Breakdown Voltage ≥35kv ≥55kv ≥60 ~75kv


Mobile Two-Stage Insulating Oil Filtration Plant (ZYD-M-50)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now