• PLC Operation Automatic Dielectric Oil Filtration Machine (ZYD-50)
  • PLC Operation Automatic Dielectric Oil Filtration Machine (ZYD-50)
  • PLC Operation Automatic Dielectric Oil Filtration Machine (ZYD-50)
  • PLC Operation Automatic Dielectric Oil Filtration Machine (ZYD-50)
  • PLC Operation Automatic Dielectric Oil Filtration Machine (ZYD-50)
  • PLC Operation Automatic Dielectric Oil Filtration Machine (ZYD-50)

PLC Operation Automatic Dielectric Oil Filtration Machine (ZYD-50)

Structure: Mobile
Usage: Solid-Liquid Separation
Type: Suction Filter
Mechanical Principle: Vacuum
Color: Yellow, Blue, Green
Power Supply: 380V/415V/480V
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Chongqing, China
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)

Basic Info.

Model NO.
ZYD-50
Heating Power
45kw
Weight
600 Kg
Size
1800X1000X1900 Mm
Delivery Date
Within 7 Days After Payment
Payment Term
T/T or L/C
Price Terms
FOB, CIF, CFR
Transport Package
Wooden Case
Specification
CE, SGS
Trademark
TOP
Origin
Chongqing, China
HS Code
84212990
Production Capacity
1000 Sets/Month

Product Description

PLC operation of dielectric oil filtration machine (ZYD)

Removes water, trace water from oil
Reduces combustible gases and oxygen
Improves oil dielectric values
Improves transformer power factor
Extends oil service life
Extends transformer service life and reliability

Why purify transformer oil?

Maybe the first question should be, "why is it important to have purified oil in a transformer?" Dissolved gasses in transformer oil can cause arcing, corona discharges, and overheating--reducing the electrical efficiency and lifetime of the transformer.Likewise, water contamination at levels as low as 30 ppm (parts per million) can adversely affect the insulating strength of the oil.With ever-increasing standards for energy efficiency of power distribution transformers, the need to effectively degas will become even more important in the future.Particles contamination will also affect the function of insulating oil.So we need to clean used transformer oil.


Characteristics:
1.Ideal choice for purification and regeneration of insulation oil, especially transformer oil

2.Reduce free water content down to 3ppm or less, gas to 0.1%, impurity to 0.5 micron.

3.Improve breakdown voltage to 80kv

4.Fluid cleanness reach to NAS6 or better

5.Large power transmission equipments above 110kv available,useful

6.Equipped with roots pump, powerful double-stage vacuum system,poweful dehydrating and degassing efficiency

7.Continuously working for 150 hours

8.Coalescence-separation technology

9.Duplex 3D evaporation technology and precise multi-stage filtration system

10.Carbon fiber infrared heating system,heating uniformity

11.Automatic double-infrared liquid controller and pressure protector

12.Interlocked protective system,safe and reliable operation

13.Automatic back-flushing system,hi-automazation and convenient operation

Oil purifier, oil filtration, oil purification, oil filter, oil treatment, oil saving, oil recycling, oil processing, oil filtering, energy saving, oil regeneration, oil processor, oil filter, oil process, oil purify, oil regenerating, oil restoration, waste oil disposal, oil reclaimed, oil reclaiming, waste oil management, oil regenerate, oil reconditioned, oil reconstituted, oil restituting, oil recovering, oil recycle, oil reclamation, oil refinery, oil separator, oil separation, oil purifiers, oil recondition, oil dehydrator, oil separator

Our oil filtration machine:
Series ZY Single-Stage Vacuum Transformer Oil Purifier
Series ZYD Double High Vacuum Transformer Oil Purifier
Series ZYB Multiply-Function insulating oil treatment machine
Series TY Turbine Oil Purification Apparatus
Series TYA Lubricating oil/ hydraulic oil purification unit
Series TYB Portable light Fuel oil purification machine
Series TYD Vacuum dehydrator
Series TYF Phosphate ester fire-resistance oil purifier
Series PL Plate pressure oil purifier
Series TYD Vacuum dehydrator
Series EFD Explosion protection filtration machine
Series BAM Press filtration system
Series ZKCC Vacuum pumping device
Series COP Cooking oil purification machine
Series CYS Centrifugal oil purification machine
Series JL Portable oil filtering and oiling machine
Series EOR series waste engine oil recycling system


Test equipment
1.Transformer oil Breakdown voltage Tester ( BDV test kit) series IIJ-II
2.Acidity tester model ACD-3000I
3.Karl Fischer Water content Tester Model TP-6A / model TP-2100
4.Fully automatic Interfacial Tension Analyzer model IT-800
5.Gas-Chromatography transformer oil gas analyzer model DGA2013-1
6.Kinematic Viscosity tester model VST-8 /model VST-2000
7.Flash point tester (open cup) model TPO-3000
8.Flash point tester (close cup) model TPC-3000
9.TAN-DELTA TESTER,10kV Capacitance and Dissipation Factor Test Set model CDEF
10.CT/PT tester model TPVA-404
11.Transformer turn ratio tester model HYG-II
12.Relaying Protection Tester model TPJB-III

Parameter:
Item Unit ZYD-A-30 ZYD-A-50 ZYD-A-100 ZYD-A-150 ZYD-A-200 ZYD-A-250 ZYD-A-300
Flow rate L/min 30 50 100 150 200 250 300
Working vacuum degree MPa -0.08 ~ -0.099
Working pressure MPa ≤0.3
Temperature range ºC 20 ~ 80
Power supply   380V/50HZ/3Ph 5 wire(as customer's requirement)
Normal working hour H ≥ 4000
Continuous working hour H 150
Working noise dB(A) 70 70 70 75 75 75 75
Heating power KW 28 30 45 60 75 90 120
Total power KW 35.5 37.5 52.5 71.4 86.5 102.5 135
Outlet(inlet) caliber   mm φ25 φ32 φ42 φ50 φ50 φ60 φ60
Weight Kg 600 800 1050 1400 1800 2000 2200
Size L mm 1500 1600 1800 1900 2000 2100 2200
W mm 800 850 1100 1150 1200 1200 1200
H mm 1600 1700 1900 2000 2100 2200 2300
Index after filtering Breakdown voltage kV ≥7
Moisture content PPM ≤3
Gas content % 0.1
Impurity size μm ≤1(customizable)
 

Transformer Oil Purifier Machine (Double Stage Vacuum)
ZYD Double Stage Vacuum Insulating Oil Purification Machine
ZYD-A PLC Fully Automatic Transformer Oil Filtration Machine
ZYD-M Outdoor Mobile Transformer Oil Purification Plant
ZYD-W Fully Enclosed Insulating Oil Purifier Machine
ZYD-S Trailer Open Type Transformer Oil Cleaning Machine
ZYD-Ex Explosion-Proof Vacuum Transformer Oil Purifier
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now