Current Transformer Testing Equipment, Transformer Ratio Tester, Transformer Turn Ratio Meter manufacturer / supplier in China, offering Multiply Functions TTR Transformer Turns Ratio Analyzer (TPOM-901), Oil Surface Tension Tester (IT-800P), Automatic Diesel Oil Moisture Tester (TP-2100) and so on.

(/ )

Supplier Homepage Product Petroleum Products Testing Equipment Multiply Functions TTR Transformer Turns Ratio Analyzer (TPOM-901)

Multiply Functions TTR Transformer Turns Ratio Analyzer (TPOM-901)

FOB Price: US $2,000-5,000 / Set
Min. Order: 1 Set
Min. Order FOB Price
1 Set US $2,000-5,000/ Set
Get Latest Price
Port: Chongqing, China
Production Capacity: 500 Sets/Month
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: TPOM-901
  • Maxcapacity: <1000KN
  • Load Way: Electronic Load
  • Display: Digital
  • Weight: 0-100Kg
  • Condition: New
  • Packing Type: Wooden Case
  • Transport Package: Standard Export Wooden Case Per Set
  • Origin: Chongqing, China
  • Type: Universal Testing Machine
  • Accuracy Grade: 0.5
  • Loading Method: Static Load
  • Control: Computer Control
  • Power Source: AC220V
  • Power Supply: Customizable
  • Trademark: TOP
  • Specification: SGS, CE, ISO
  • HS Code: 90278099
Product Description
Multiply functions TTR transformer turns ratio analyzer(TPOM-901)
1.Small size and portable;
2. Low price with reliable performance.
3. meet IEC standard

1 Introduction
TPOM-901 is applied to measure the voltage ratio of three or single phase transformer. All the data and test 
results are shown on a 320*240 LCD screen. All the test results could be printed by the micro printer or saved in the storage of the tester. The tester has a good performance on auto protection and anti-disturb. 

2 Main functions
1. The voltage ratio measurement of three or singe phase transformer
2. The group vector measurement of three phase transformer.
3. The polarity measurement of single phase transformer or CT/PT
4. Voltage ratio error calculation 
5. Voltage ratio range calculation of three phase transformer
6. Current transformer ratio measurement
7. Excitation current measurement in ratio testing
8. Reproduction the AC test voltage from power source to reduce the effects of bad power source 
9. Save the test results in the memory internal the tester
10. Print the test results by micro printer
11. Reverse connection detect unit to prevent the high voltage injected to the operate 
12. Over current protection in test voltage
13. Upload the test results to make word report by RS232 interface 
 
3 Technical parameters
 
Ratio measurement range1-10000
Group measurement1-12
Phase measurement error1 degree
Ratio measurement error1-2000 ± 0.2%   2000-10000  ± 0.5%
Power supplyAC220V ± 10%, 50Hz
Size400*350*200



Trustable technical and after sale serivece
1. Long-term warranty of 2 years.
2. Provide best spare parts at low price (some for free).
3. Provide timely reply and technical support.
4. If anything wrong with the equipment, we would give prompt response and provide solution within 24 hours.
5. If there is technological innovation, we would guide our customer to upgrade.

 [Key words: current transformer analyzer, automatic transformer tester, current transformer tester, transformer turns ratio tester, 3 phase transformer turn ratio tester, CT ratio tester, transformer turn ratio, machinery for transformer testing, transformer tester, ttr transformer turns ratio tester, current transformer analyzer, ct analyzer, test transformer, transformer testing, ttr tester, transformer ttr tester, transformer ct pt testing equipment, resistance tester, phase error test, ctpt current transformer testing equipment, ct pt tester, ct pt transformer tester, ct/pt analyzer, ct pt testing equipment, ttr tester, polarity tester, current transformer transformation ratio test, transformer ct pt testing equipment, distribution transformer testing equipment, power transformer testing equipment, current transformer ratio testing instrument, transformer ttr machine... ] 

Test equipment
1.Transformer oil Breakdown voltage Tester ( BDV test kit) series IIJ-II
2. Acidity tester model ACD-3000I
3. Karl Fischer Water content Tester Model TP-6A / model TP-2100
4. Fully automatic Interfacial Tension Analyzer model IT-800
5.Gas-Chromatography transformer oil gas analyzer model DGA2013-1
6.Multi-functional Vibration tester model TYD-2000
7.Automatic Freezing Point & Pour Point Tester model PT-2000
8. Kinematic Viscosity tester model VST-8 /model VST-2000
9. Flash point tester (open cup) model TPO-3000
10. Flash point tester (close cup) model TPC-3000
11.TAN-DELTA TESTER,10kV Capacitance and Dissipation Factor Test Set model CDEF
12. Automatic Freezing Point & Pour Point Tester model TP-501Z
13.Determination of foaming characteristic of lubricating oil model SD-12579
14. Earth resistance tester model HYDW-II 
15. Coil Resistance Tester (TPZC-40)
16. CT/PT tester model TPVA-404
17.Transformer turn ratio tester model HYG-II
18. Relaying Protection Tester model TPJB-III
19. Digital Grounding Resistance Tester model TP2571-II
20.DC High Voltage Generator model ZGF
21.Underground water/gold detector model TP-UWD
Send your message to this supplier
Avatar
Mr. Tim Gong
Sales
*From:
To: Mr. Tim Gong
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now