Gold Member Since 2014
Audited Supplier
Chongqing TOP Oil Purifier Co., Ltd.

Insulation Oil Loss Tester, Dielectric Loss Factor, Dielectric Loss Meter manufacturer / supplier in China, offering Transformer Oil Tan Delta Analyzer (DLT0820), Economical Portable Insulating Oil Filtration Machine (ZY-30), Continuously Vacuum Insulation Oil Regeneration Machine (ZYB-20) and so on.

(/ )

Supplier Homepage Product Petroleum Products Testing Equipment Transformer Oil Tan Delta Analyzer (DLT0820)

Transformer Oil Tan Delta Analyzer (DLT0820)

FOB Price: US $4,000-6,000 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $4,000-6,000/ Piece
Get Latest Price
Port: Shanghai, China
Production Capacity: 1000 Sets/ Month
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: DLT0820
  • Maxcapacity: >1000KN
  • Load Way: Mechanical Load
  • Display: Needle
  • Weight: 0-100Kg
  • Oil Cylinder Position: -
  • Net Weight: 20 Kg
  • Output Voltage: 0-80kv/ 0-100kv
  • Transport Package: Wooden Case
  • Origin: Chongqing, China
  • Type: Universal Testing Machine
  • Accuracy Grade: 0.5
  • Loading Method: -
  • Control: Manual Control
  • Power Source: AC220V
  • Size: Small
  • Power Supply: 220V 50Hz
  • Trademark: TOP
  • Specification: CE, SGS
  • HS Code: 90318090
Product Description
Transformer oil Tan Delta Analyzer (DLT0820)
1. High quality, portable, easy to use
2. Compact and ultra-light
3. Meet IEC

Oil dielectric loss tester based on IEC and the relevant provisions of the state, to play their own technological superiority, and carefully developed high-precision, digital instrumentation. The apparatus uses high-frequency induction heating, even heating, fast temperature rise speed, short time. The microprocessor control and calculation, realize automation, capacitance and dielectric loss of high measuring precision, stability, good repeatability of data. Output voltage of 0 ~ 2000V is continuous and adjustable, suitable for different sample the voltage level required. Widely used in transformer oil, capacitor oil and cable oil dielectric loss measurement.

Two, safety measures
1, the use of the apparatus before must carefully read this manual.
2, the operator should have the general electrical equipment or instruments to use common sense.
3, the instrument should avoid vibration.
4, the apparatus must be grounded reliably, to prevent the risk of electric shock.
5, after the test, press the reset button, turn off the power switch, and is charged each test cable and replace the oil sample.
6, equipment maintenance, must not in the case of electricity, or high risk.
7, prohibit the empty cup if heating, heating temperature, must be added to the measurement of dielectric loss of oil and oil

Three, performance characteristics
1, using electromagnetic induction heating technique, even heating, fast temperature rise speed, short time.
2, the output voltage 500V ~ 2000V is continuous and adjustable, suitable for different sample the voltage level required.
3, the temperature control is accurate, is not affected by environment temperature influence.
4, high measurement accuracy, stable, reproducible data.
5, a boot detection circuit, no grounding or earthing is not good to give a hint.
6, a short-circuit protection circuit, short circuit and high voltage output circuit.
Four, technical indicators
measurement rangeCapacitance: 1pF ~ 200pF
Dielectric loss: 0 ~ 10%
measurement precisionCapacitance: + ( 0.5% C+1pF )
Dielectric loss: + ( 1% D+0.00008 )
resolution
Dielectric loss
0.01pF capacitor
1 x 10-5
range of temperatureRoom temperature to 100 DEG C
the precision of temperature control+ / - 0.5 DEG C
the output voltage0 ~ 2000V continuously adjustable
a working power supplyAC220V + 10% 50HZ
the use of temperature0 ~ 40
the relative humidityLess than or equal to 90% without dew
heavy weight10kg


Our oil tester
1. Transformer oil Breakdown voltage Tester (BDV test kit) series IIJ-II
2. Acidity tester model ACD-3000I
3. Karl Fischer Water content Tester Model TP-6A / model TP-2100
4. Fully automatic Interfacial Tension Analyzer model IT-800
5. Gas-Chromatography transformer oil gas analyzer model DGA2013-1
6. Multi-functional Vibration tester model TYD-2000
7. Consolidation Point Determinator model PT-2000
8. Kinematic Viscosity tester model VST-8 /model VST-2000
9. Flash point tester (open cup) model TPO-3000
10. Flash point tester (close cup) model TPC-3000
11. TAN-DELTA TESTER, 10kV Capacitance and Dissipation Factor Test Set model CDEF
12. Automatic Freezing Point & Pour Point Tester model TP-501Z
13. Determination of foaming characteristic of lubricating oil model SD-12579
14. Earth resistance tester model HYDW-II
15. Coil Resistance Tester (TPZC-40)
16. CT/PT tester model TPVA-404
17. Transformer turn ratio tester model HYG-II
18. Relaying Protection Tester model TPJB-III
19. Digital Grounding Resistance Tester model TP2571-II
20. DC High Voltage Generator model ZGF
21. Underground water/gold detector model TP-UWD

Key words:  dielectric loss test, insulating oil dielectric loss tester, dielectric loss transformer oil tester, dielectric loss testing testing equipment, dielectric loss meter, insulating oil loss tester, transformer oil tester, oil dielectric loss tester, insulating oil tan delta tester, tan delta measurement, oil tan delta tester, transformer oil tan delta testing equipment, oil dielectric loss analyzer, anti-interference dielectric loss measuring, capacitance dielectric loss measuring instrument, capacitance measuring, dielectric loss factor
Send your message to this supplier
Avatar
Ms. Abby Xiao
Manager
*From:
To: Ms. Abby Xiao
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now